Table of Contents
ToggleProduct Overview
The KITOZER 100kW central PV inverter is a floor standing three phase inverter for commercial and industrial solar plants from 100 kW to 500 kW. Built on a high efficiency IGBT bridge with LCL filter, the inverter achieves 98.7 percent peak efficiency. A 10 inch touch screen shows real time yield, DC string voltage, and grid parameters, while redundant Ethernet ports support SCADA integration. The cabinet is designed for indoor or shaded outdoor installation. The 1500 Vdc design reduces cable losses and combiner box count on large arrays.
Technical Specifications
Input: three phase 400 V, 50 or 60 Hz. Output: 100 kW continuous. DC side: four MPPT, 500 to 1500 Vdc, 40 A per MPPT. Maximum DC input 150 kW. Efficiency 98.7 percent peak, 98.2 percent European. THDi less than 2 percent, power factor adjustable 0.8 to 0.8. Islanding compliant with VDE 0126, G99, EN 50549. Communication: dual Ethernet, Modbus TCP, optional 4G. Protection: DC switch, type 2 surge, arc fault. Enclosure IP54, weight 180 kg, dimensions 800 by 600 by 1800 mm. Operating temperature minus 25 to plus 60 degrees. Noise level below 62 dB(A). Standards CE, IEC 62109, KITOZER 5 year warranty.
Application Scenarios
The 100 kW central inverter is used at factory rooftops, parking canopy solar, and small ground mount arrays rated up to 500 kW. It is also specified at logistics centers and warehouse rooftops that want a single inverter per building. The 1500 Vdc design reduces cable losses on large arrays, which improves overall plant yield. It is also deployed at school campuses, at hospital solar arrays, at municipal building rooftops, and at cold storage facilities that need to offset daytime peak demand.
Advantages and Features
The 1500 Vdc design reduces string cable cross section and combiner box count, cutting balance of system cost by up to 15 percent compared with 1000 V systems. Four MPPT channels handle complex string layouts. The power factor is adjustable, providing reactive power support. Redundant fans ensure continuous operation even if one fan fails. The cloud portal shows per string yield and supports automated reporting. The dual Ethernet ports support redundant SCADA communication.
Installation and Maintenance
Place the inverter on a level floor in a ventilated room. Connect the DC strings via the integrated DC switch, and the AC side to the LV distribution panel via a 250 A three phase MCCB. Connect the dual Ethernet to the site network. Maintenance includes cleaning air filters every six months and inspecting DC connectors annually. Fans are field replaceable. The unit carries a 5 year warranty.
Reliability and Quality
Each inverter is burned in for 24 hours at full load. The enclosure passes salt spray and vibration tests. The redundant fans are rated for 50,000 hours. The KITOZER cloud portal stores per string yield and fault logs for twelve months. Regional service partners provide on site support within 48 hours. The unit carries a 5 year warranty with a 10 year extension available.
Price
From $5,980 per unit. Contact plus 86 13922289957 for C&I solar project pricing. Lead time 25 days.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com