KITOZER
KITOZER

KITOZER 1MW Central Storage PCS For Grid Scale Plant

Product Overview

The KITOZER 1MW central PCS is a skid mounted power conversion station for grid scale battery energy storage plants rated from 5 MWh to 100 MWh. Four 250 kW converter units are paralleled inside a 40 ft outdoor container, with a built in step up transformer and MV switchgear bay. The PCS supports both grid following and grid forming control, and it can provide primary frequency response, voltage support, and black start. A central energy management screen shows real time power flow, battery state of health, and grid parameters across the whole plant. The skid includes redundant coolant loops, a fire suppression system, and a smoke detection system.

Technical Specifications

AC side: three phase 400 V LV, 50 or 60 Hz, 1 MW continuous, with built in 1250 kVA step up transformer to 10 kV or 35 kV MV. DC side: 600 to 1500 Vdc battery, 1600 A maximum. Efficiency 98.5 percent peak. THDi less than 2 percent, power factor adjustable 0.8 to 0.8. Communication: dual Ethernet, CAN, Modbus TCP, IEC 61850, DNP3. Cooling: liquid cooled with redundant loop. Protection: DC over voltage, AC over voltage, islanding, over temperature, arc fault, smoke detection, MV protection relay. Enclosure IP54, weight 12000 kg, dimensions 12192 by 2438 by 2896 mm 40 ft container. Standards CE, IEC 62109, IEC 61850, KITOZER 5 year warranty.

Application Scenarios

The 1 MW skid is the standard building block for utility scale battery plants: a 50 MWh project uses fifty skids, a 20 MWh project uses twenty. It is also deployed at wind and solar farms that need to firm variable renewable output, and at grid nodes that need fast frequency response. The built in MV transformer and switchgear reduce on site engineering to a single MV cable termination, which cuts installation time from months to weeks. It is also specified at large commercial campuses, at mining operations, and at island microgrids that need multi megawatt storage.

Advantages and Features

Four parallel converters deliver N plus two redundancy: the skid stays online at 750 kW even with two converters down. The built in MV transformer and switchgear mean no separate outdoor substation is required, which reduces civil works. The grid forming function provides synthetic inertia and black start, making the skid suitable for islanded microgrids. The energy management system supports automated dispatch based on market signals and weather forecasts, maximizing revenue under ancillary service tariffs. The skid is precommissioned at the factory, so on site commissioning takes only days.

Installation and Maintenance

Place the skid on a reinforced concrete pad with crane access. Terminate the MV cable at the built in switchgear, and connect the DC side to the battery array via a 2000 A DC bus duct. Commissioning requires a factory commissioning engineer and a full protection relay test. Monthly checks cover coolant level, MV insulation, and surge counter readings. Annual service includes heat exchanger cleaning, MV transformer oil test, and firmware update. Keep a spare 250 kW converter on site.

Reliability and Quality

The skid is burned in for 72 hours at full load. The MV transformer passes oil breakdown test and insulation test. The liquid cooled loop is pressure tested for 48 hours. The KITOZER cloud portal monitors every converter, pump, and relay in real time. The skid carries a 5 year warranty with a 10 year extension available. Regional service partners provide on site response within 24 hours.

Price

From $128,000 per skid including MV transformer. Contact plus 86 13922289957 for multi skid plant EPC pricing. Lead time 60 days.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart