KITOZER Fire Damper: 70C DN500 Galvanized Blade Damper

Product Overview

The KITOZER 70 degrees Celsius DN500 fire damper is a galvanized steel blade damper installed in HVAC ducts that penetrate fire-rated walls or floors. When duct air temperature reaches 70 degrees Celsius, the fusible link melts, a spring closes the blade, and the damper seals the duct to prevent smoke and flame from spreading between compartments. The damper ships with a mounting flange, fusible link, and a microswitch that sends a closed signal to the building management system.

Technical Specifications

Size 500 x 320 mm rectangular or DN500 round, activation temperature 70 degrees Celsius fusible link, blade galvanized steel 1.5 mm, frame galvanized steel 2 mm, seal intumescent or silicone, leakage class C at 1000 Pa, actuation spring return, microswitch SPDT, operating voltage 24V or 220V, CCCF certified, GB 15930, maximum working temperature 70 degrees Celsius ambient, weight 18 kg. Optional motorized actuator for remote test.

Application Scenarios

This fire damper is installed wherever supply or return air ducts cross fire-rated walls, floors, or shaft enclosures, including commercial buildings, hospitals, shopping malls, underground parking, and industrial plants. The 70 degrees Celsius rating is standard for general HVAC ducts. For exhaust ducts handling grease or hot process air, KITOZER offers 150 degrees Celsius kitchen grease dampers and 280 degrees Celsius smoke exhaust dampers. KITOZER also provides rectangular and round dampers in all common duct sizes, as well as custom sizes for non-standard shafts.

Key Advantages

The galvanized steel frame survives decades in conditioned ductwork without painting, and the intumescent seal expands when heated to provide a tight smoke seal. The spring return closes the damper within seconds of link melting, even if fan power is lost. The microswitch confirms closed position to the BMS, which is required by modern building codes. KITOZER ships each damper with a factory calibration certificate and mounting templates, simplifying installation on site.

Installation and Maintenance Recommendations

Install the damper within 200 mm of the fire wall penetration, and seal the annular gap with fire-rated mortar. Leave at least 200 mm clearance on the actuator side for inspection and link replacement. Test the damper quarterly by manually pushing the test lever and confirming the blade closes and the microswitch changes state. Replace the fusible link every 5 years, or immediately after any activation. Do not paint over the fusible link or blade, and keep the damper accessible from a walkway rather than burying it inside a ceiling cavity.

Price

From $95 per damper. Contact +86 13922289957 for fire damper pricing and sizes.