Table of Contents
ToggleProduct Overview
The KITOZER 280 degrees Celsius DN630 smoke exhaust damper is a motorized blade damper installed in smoke extraction ducts to open automatically on fire alarm and remain open even when hot smoke at 280 degrees Celsius passes through for 30 minutes. Unlike ordinary fire dampers that close, smoke exhaust dampers open to route smoke from the fire floor to the dedicated exhaust fan, maintaining tenable conditions on evacuation routes. The damper is driven by a 24V or 220V motorized actuator with fail-safe spring return, and includes position feedback to the fire alarm panel.
Technical Specifications
Size DN630 round or 630 x 400 mm rectangular, thermal rating 280 degrees Celsius for 30 minutes, blade stainless steel 1.5 mm, frame galvanized steel 2 mm, actuator 24V DC or 220V AC, spring return fail-safe open on alarm, position feedback 4 to 20 mA or SPDT microswitch, leakage class C at 1500 Pa, CCCF certified, GB 15930, response time under 30 seconds, weight 35 kg. Operating ambient minus 10 to 50 degrees Celsius.
Application Scenarios
This damper is installed in the smoke extraction ducts of underground car parks, high-rise atria, shopping mall arcades, warehouse mezzanines, and theater lobbies. On a fire floor, the fire alarm panel opens the corresponding smoke exhaust damper and starts the exhaust fan, while dampers on non-fire floors stay closed. The 280 degrees Celsius rating ensures the damper survives hot smoke from a fully developed fire, which is required by GB 51251 for dedicated smoke extraction systems.
Key Advantages
The stainless steel blade resists corrosion from condensation in exhaust ducts, and the intumescent seal maintains smoke tightness even after repeated thermal cycles. The spring return actuator fails safe to open on loss of power, which is the correct fail state for smoke exhaust. Position feedback allows the fire control room to confirm that each damper has moved, which is essential for system verification. KITOZER supplies the damper pre-wired with the actuator, so the contractor only needs to land 24V power and feedback wires.
Installation and Maintenance Recommendations
Install the damper with the actuator side accessible, and allow 300 mm clearance for actuator removal. Connect the control wiring to the fire alarm panel using fire-rated cable. Test the damper semiannually by commanding open and closed from the panel, and verify the position feedback matches. Inspect the blade and seal annually for soot accumulation, and clean with a soft brush. Replace the actuator every 10 years, and keep a spare actuator on site to minimize downtime.
Price
From $320 per damper. Contact +86 13922289957 for smoke exhaust damper pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com