The KITOZER 150RT glycol chiller delivers stable low temperature coolant for industrial process cooling, brewery wort chilling, concrete curing cooling, and ice rink secondary loops. Using a flooded shell and tube evaporator designed for ethylene or propylene glycol solutions, the chiller can supply coolant at minus 5 C or even minus 10 C with appropriate glycol concentration. The robust screw compressor and large evaporator ensure reliable operation under continuous process loads.
Table of Contents
ToggleProduct Overview
KITOZER glycol chillers are air cooled or water cooled depending on site preference. The air cooled version uses copper tube aluminum fin condenser with EC fans. The evaporator is designed with larger tube diameter and low velocity to minimize glycol pressure drop and prevent film freezing. A crankcase heater, suction accumulator, and hot gas bypass are standard to protect the compressor during low load conditions. The controller displays supply and return glycol temperature, condenser pressure, and alarm status.
Technical Specifications
Cooling capacity 150 RT (527 kW) at minus 5 C glycol supply, 30 percent ethylene glycol. Evaporator flow 90 m3 per h. Operating range minus 10 C to plus 20 C glycol supply. Compressor twin screw, 90 kW. Power supply 380 V 50 Hz. Refrigerant R448A or R513A. Condenser air flow 80,000 m3 per h. Fan motor total 7.5 kW. Sound level 75 dB(A) at 10 m. Weight 5200 kg. CE certified, 3 year warranty.
Application Scenarios
Typical applications include food and beverage process cooling, dairy and brewery wort chilling, concrete batch plant cooling, chemical reactor jacket cooling, and artificial ice rinks. The chiller can also serve data center secondary loops in cold climates where glycol antifreeze is required. When paired with a buffer tank, the chiller handles fluctuating process loads without short cycling. It is a common choice for cold storage distribution centers requiring secondary coolant loops.
Advantages and Features
Low temperature evaporator with enhanced tubes prevents glycol film freezing and protects against tube burst. Hot gas bypass allows stable operation at low process loads down to 25 percent capacity. The suction accumulator protects the compressor from liquid slugging. EC fans reduce sound and energy. The unit is pre charged with refrigerant and pressure tested at the factory. Optional pump tank skid includes circulation pump, buffer tank, and expansion vessel for a complete packaged system.
Installation and Maintenance
Install the chiller outdoors or in a well ventilated mechanical room. Verify glycol concentration matches the design low ambient temperature. Use braided rubber or stainless flexible hoses on glycol piping. Install a suction side strainer. Commissioning includes verifying glycol flow, evaporator outlet superheat, and hot gas bypass setting. Quarterly maintenance includes condenser coil cleaning, oil sight glass check, and electrical terminal torque. Annually inspect glycol for freezing point and corrosion inhibitor concentration, and top up as needed.
Price
From $22,800 per unit. Contact KITOZER for process specific engineering and pump tank skid quote.