The KITOZER spring vibration isolator pad isolates chillers, pumps, cooling towers, and air handling units from building structure, reducing noise and structure borne vibration. The spring mount achieves 95 percent isolation efficiency at 15 Hz natural frequency, effectively blocking vibration from rotating equipment at 1500 rpm and above. It is essential for installations on upper floors, hospitals, recording studios, and residential buildings where low frequency noise is a concern.
Table of Contents
ToggleProduct Overview
Each isolator consists of a nested steel spring with rubber acoustic pad, housed in a welded steel housing with top and bottom connection plates. The spring is designed for 25 to 50 percent deflection under load, giving a natural frequency of 3 to 5 Hz. The housing includes a lateral restraint to prevent horizontal movement during operation. Isolators are available in various load ratings from 50 kg to 1000 kg per mount to match equipment weight.
Technical Specifications
Standard size 100 x 100 x 50 mm. Load rating 100 to 500 kg per mount. Natural frequency 3 to 5 Hz. Deflection 25 mm. Steel spring epoxy painted. Rubber pad 5 mm neoprene. Lateral restraint included. Operating temperature minus 20 C to 80 C. CE certified, 5 year warranty.
Application Scenarios
Install four or more isolators under each chiller, pump, cooling tower, or air handling unit base frame. They are also used under generator sets, elevator machines, and transformer rooms. For floor mounted equipment, the isolators sit on a concrete housekeeping pad. For ceiling mounted air handlers, use spring hangers instead of floor mounts. Proper isolation prevents low frequency rumble from transmitting through slabs and beams.
Advantages and Features
Steel springs provide much lower natural frequency than rubber pads, isolating frequencies that rubber cannot. The neoprene acoustic pad prevents high frequency flanking noise through the spring coil. Lateral restraint prevents equipment walk during startup and shutdown. Welded housing prevents rust. Adjustable leveling bolt allows fine alignment. The isolators are reusable during equipment relocation. Load rated selection ensures deflection stays in design range.
Installation and Maintenance
Place isolators directly under equipment mounting points. Verify load per isolator does not exceed rated capacity. Tighten anchor bolts to allow the spring to settle freely. Do not grout over the isolators. After installation, run the equipment and measure vibration on the floor adjacent to the pad; it should be below 0.5 mm per second. Inspect springs annually for corrosion or set. Replace isolators if deflection exceeds 50 mm or if the rubber pad shows cracking.
Price
From $18 per isolator. Contact KITOZER for load rating selection and hanger spring type.