The KITOZER 750GPM @ 100m vertical split case sprinkler pump is engineered as the dedicated water supply pump for automatic sprinkler systems in high-rise commercial towers, hotels, and large industrial plants. The vertical split case design places suction and discharge nozzles on the same centerline, reducing floor space by up to 40% compared with horizontal end-suction units. The double suction impeller minimizes axial thrust and allows flow rates up to 750 gallons per minute while maintaining stable head of 100 meters across the entire sprinkler demand curve. KITOZER supplies the pump as a complete skid with base frame, couplings, pressure gauges, test header, and drain manifold for fast installation.
The vertical configuration is particularly valuable in deep basement pump rooms where horizontal length is constrained by the building footprint. Because the suction and discharge nozzles point upward, the piping can run directly above the pump on overhead supports, eliminating the long horizontal elbows common with end-suction pumps. The double suction impeller also splits the flow path into two symmetric inlets, which halves the velocity through each side and reduces the risk of cavitation at high flow rates. This is especially important when the sprinkler system demand grows from a few open heads to dozens during a real fire event.
Technical Specifications
Rated flow 750 US GPM (170 cubic meters per hour), rated head 100 meters, motor power 75 kW, speed 2950 rpm, three phase 380V/50Hz, suction flange DN200, discharge flange DN150, maximum working pressure 1.8 MPa, NPSHR 5.0 meters, efficiency 81%, impeller double suction cast bronze optional, shaft 42CrMo with stainless steel sleeve, mechanical seal John Crane type, base frame welded steel. CCCF and ISO 9001 certified, optional UL/FM listing. IP55 motor, Class F insulation, service factor 1.15, S1 duty.
The pump casing is designed as a vertical split case, with the upper half removable after removing the tie bolts. This allows inspection of the impeller, wear rings, and seal without lifting the pump off the base frame. The bearing housing uses two anti-friction bearings, one on each side of the impeller, grease lubricated and fitted with a temperature sensor for remote monitoring. The shaft seal is a single mechanical seal with a flush port, and the seal chamber can be vented to release air pockets during priming. The base frame includes integrated drip rails that route seal leakage to a central drain, keeping the pump room floor dry.
Application Scenarios
This sprinkler pump is intended for automatic wet pipe sprinkler systems in Class I to Class IV occupancies, including high-rise office buildings above 150 meters, five-star hotels, convention centers, hospitals, underground shopping streets, and multi-story logistics warehouses. It can serve as the lead pump in a duty-standby pair with one pump running and one pump on auto standby, switching over on pressure loss or pump failure. The vertical configuration is particularly suitable for pump rooms with restricted length or where suction and discharge piping must run in parallel above the floor.
For high-rise towers above 200 meters, the pump is often installed in a series configuration with a roof-mounted booster pump, so the ground floor pump supplies the mid-level zone and the roof pump supplies the upper zone. The same model is also used as a deluge pump for open sprinkler systems in parking garages and aircraft hangars, where the valve opens all heads at once and the pump must deliver full flow immediately. KITOZER can provide a horizontal split case variant for projects that prefer horizontal orientation, as well as a diesel engine driven variant for sites without reliable three-phase power.
Key Advantages
The double suction impeller provides superior resistance to cavitation and delivers flat head curves that protect sprinkler heads from pressure surges when the system first activates. The vertical split case allows internal access without disconnecting main piping, which simplifies annual inspection and seal replacement. The paired electric motor uses high-grade silicon steel laminations for low temperature rise, and the pump casing is pressure tested at 1.5 times working pressure. KITOZER factory testing includes flow, head, vibration, noise, and seal leak checks before shipment, and every unit ships with a signed performance curve traceable to the rated point.
The flat head curve is a critical safety feature, because sprinkler systems depend on stable pressure as more heads open. A steep curve would cause pressure to spike as flow drops, potentially rupturing older sprinkler heads or piping. The KITOZER curve is engineered so pressure rises by less than 10% from rated flow to shutoff, well within NFPA 20 limits. The motor is sized so the brake horsepower at shutoff does not exceed the motor service factor, preventing overload during a closed-head test. These design details make the pump compatible with variable speed drive retrofits if the owner later decides to add pressure maintenance control.
Installation and Maintenance Recommendations
Anchor the skid to a concrete foundation at least 200 mm thick and four times the pump mass, using bolt-down holes provided on the base frame. Align motor and pump shafts within 0.05 mm coupling tolerance after piping is connected, because piping strain is the leading cause of premature bearing failure. Install a 50 mm diameter test and drain header connected to the nearest drain pit, so the monthly flow test can discharge safely without spraying the pump room. Lubricate bearings with lithium-based grease every 4000 running hours, inspect the mechanical seal every six months, and run the pump weekly for at least 5 minutes under no-flow conditions to verify priming and rotation.
During the first month of operation, recheck the shaft alignment twice, because new couplings and base frames settle under thermal cycling. Record suction and discharge pressure, motor current, and bearing temperature on the monthly test sheet, and compare readings to the commissioning baseline. Vibration readings should be taken annually with a portable vibration meter, and compared to the ISO 10816 grade limits. Spare wear rings and a mechanical seal kit should be kept on site, because these are the components most likely to need replacement after 5 years of service. KITOZER recommends a 5-year overhaul that includes impeller inspection, wear ring replacement, and bearing replacement.
Price
From $4,980 per set. Contact +86 13922289957 for sprinkler pump pricing and delivery schedule.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com