KITOZER Medical Shielded Room: MRI Faraday Cage 100 dB Copper

The KITOZER MRI shielded room is a medical-grade Faraday cage designed to protect magnetic resonance imaging scans from radio frequency interference. Built from 0.5 mm oxygen-free copper panels with brazed lap joints, the room achieves 100 dB attenuation from 10 MHz to 1 GHz across the Larmor frequency bands of 1.5 T and 3.0 T scanners, preventing ambient RF noise from broadcast transmitters, cellular towers, and building systems from corrupting image data. The chamber includes a magnet-compatible door, filtered penetrations for utility services, and a dedicated RF-shielded viewing window for the scanner control room.

Product Overview

MRI rooms are custom engineered for each scanner bore and site, typically 6 m by 8 m by 3.2 m interior dimensions including scanner room, equipment room, and control room. The copper panel system is installed on a non-magnetic steel frame, with all fasteners made of non-ferromagnetic material to avoid attraction to the scanner magnet. Every penetration, including power, signal, HVAC, and plumbing, uses MRI-rated filters or waveguides. The room also includes a Faraday gate test point for daily RF interference verification, and a shielded LED lighting system with integrated filters.

Technical Specifications

Shielding effectiveness: 100 dB from 10 MHz to 1 GHz, 80 dB up to 2 GHz, per IEEE 299 and NEMA MS 2. Panel: 0.5 mm oxygen-free copper, brazed lap joints, non-ferromagnetic stainless steel fasteners. Door: RF-shielded hinged door 1200 mm by 2200 mm, non-magnetic brass frame, beryllium copper finger gasket, door attenuation 100 dB. Power filter: 63 A three phase MRI-rated EMI filter, non-magnetic components, insertion loss 120 dB. HVAC: circular copper waveguide duct 400 mm diameter, cutoff 2 GHz, with HEPA and carbon filtration. Window: 800 mm by 600 mm copper mesh laminated glass, attenuation 100 dB. Penetrations: fiber-optic bulkhead for network, filtered DB9 for physiologic monitoring, waveguide for plumbing. Non-magnetic floor: aluminum honeycomb panel, load 1000 kg per square meter. Compliance: IEC 60601-1-2, NEMA MS 2, ISO 9001. KITOZER brand, 10 year shield warranty.

Application Scenarios

This room is installed in hospital radiology departments, imaging centers, and university medical schools for 1.5 T and 3.0 T MRI scanners. It is also suitable for 7 T research systems where RF interference must be even more tightly controlled. The room design supports both closed-bore and open-bore scanner configurations, and can be extended to include adjacent equipment and control rooms. Because the construction is non-magnetic, no ferromagnetic tools or fittings are permitted inside the room during installation, a requirement KITOZER crews follow as standard. The chamber is also used for MEG and EEG suites where even lower noise floors are required.

Advantages and Features

Copper construction provides stable attenuation across the Larmor frequency bands, unlike steel rooms which can introduce resonant coupling. Brazed joints eliminate gasket leakage at panel seams, a common failure point in older bolted copper rooms. All fasteners and hardware are non-ferromagnetic, preventing projectile risk near high-field magnets. KITOZER provides a daily RF test pad integrated into the room, allowing biomedical engineers to verify shielding before each patient scan. The room also integrates with the scanner vendor service network, with documented penetration locations for field service engineers. Turnkey delivery includes copper installation, door, filters, window, HVAC waveguide, and on-site RF verification testing.

Installation and Maintenance Recommendations

Site preparation requires a dedicated non-magnetic foundation with no rebar within 5 m of the scanner magnet, and a building ground grid bonded to the room copper busbar. KITOZER installation is performed by non-magnetic-tool-certified crews under a strict safety protocol, and the room is RF tested on completion with a calibrated signal source and receiver. Daily maintenance includes a quick RF gate test at start of day, visual inspection of door gaskets, and filter terminal checks. Quarterly maintenance includes door hinge adjustment, gasket cleaning, and HVAC filter replacement. Annually, the room undergoes full RF attenuation testing by a biomedical engineer. Copper interior surfaces should be polished annually to maintain conductivity, and any new equipment brought into the room must be confirmed non-magnetic before entry.

KITOZER supports every product with factory documentation including attenuation test certificates, material declarations, dimensional drawings, and installation manuals. Spare gaskets, filters, and consumables are stocked for fast delivery, and the engineering team provides application support for sizing, grounding, and system integration. All products are manufactured under ISO 9001 quality control, with incoming material inspection, in-process testing, and final factory verification before shipment. The stated warranty covers defects in materials and workmanship, and optional extended service contracts are available for critical shielded installations. Customers can request site visit support, on-site acceptance testing, and long-term maintenance planning through the Guangzhou engineering team.

Price

From $95,000 per complete MRI shielded room, including copper shell, door, filters, window, and RF verification. Contact +86 13922289957 for scanner-specific quotation.