KITOZER
KITOZER

KITOZER Automatic Self Cleaning Water Filter DN100 100 Micron

The KITOZER DN100 automatic self cleaning screen filter protects cooling water loops, chiller condenser tubes, and heat exchanger coils from suspended solids. The filter continuously removes sand, rust, biofilm, and debris without interrupting water flow. A built in pressure differential switch triggers automatic backwash when the screen reaches a pre set pressure drop, and a drain solenoid valve discharges captured solids to waste.

Traditional basket filters require manual shutdown and cleaning every few weeks. The self cleaning filter performs this automatically while the system runs, eliminating unplanned maintenance. The wedge wire screen is designed for high dirt holding capacity and cleanable by suction scanner, providing years of service without replacement.

Product Overview

The filter body is carbon steel with epoxy coating or stainless steel 304. The internal screen is wedge wire or perforated stainless steel with 100 micron or custom micron rating. A motor driven suction scanner cleans the screen from inside out during backwash. The controller offers manual, timer, and differential pressure modes, with Modbus output for BMS monitoring. The unit operates at full flow during backwash, with only a small side stream diverted to drain.

The suction scanner moves along the screen axis, sweeping a narrow slot over the screen surface. Low pressure inside the scanner nozzle pulls captured debris off the screen and out the drain. Backwash lasts 15 to 30 seconds per cycle and consumes less than 1 percent of loop flow. A motorized ball valve on the drain opens only during backwash, saving water.

Technical Specifications

Nominal size DN100, flange PN16. Flow rate 120 m3 per h. Filtration rating 100 micron (optional 50 to 2000 micron). Working pressure 10 bar. Backwash pressure 2 bar minimum. Backwash time 15 to 30 seconds per cycle. Motor power 0.12 kW. Power supply 220 V 50 Hz. Weight 85 kg. Body material carbon steel epoxy, screen SS316. CE certified, 2 year warranty.

Application Scenarios

Install this filter on cooling tower make up water, side stream filtration for cooling towers, condenser water protection, and process water supply. It is especially valuable for chillers with shell and tube condensers where tube fouling reduces efficiency. Side stream installation at 5 to 10 percent of loop flow keeps the entire loop clean. The filter is also used on irrigation water, makeup for boilers, and industrial circulating water systems.

In large cooling tower plants, side stream filters at 5 to 10 percent of loop flow remove solids that settle in the basin. In HVAC, the filter protects control valves and heat exchangers from construction debris. In manufacturing, it protects spray nozzles and cooling jackets. The filter can be sized for up to 2000 micron rating for rough screening applications.

Advantages and Features

Continuous filtration without shutdown saves maintenance labor and avoids manual screen cleaning. The stainless wedge wire screen is backwashable and reusable for 10 years or more. Low backwash water consumption reduces waste. The compact vertical design saves floor space. Differential pressure trigger avoids unnecessary backwash cycles. Modbus integration allows remote monitoring of filter condition and backwash history. Optional motorized ball valve isolates the filter for service without shutting down the loop.

Compared with sand filters, screen filters have lower water consumption during backwash and smaller footprint. Compared with manual basket filters, they never require shutdown for cleaning. The wedge wire screen provides uniform precision and does not deform under pressure.

Installation and Maintenance

Install the filter vertically with flow direction matching the arrow on the body. Provide a bypass line and isolation valves for servicing. Connect drain line to waste with an air gap. Commissioning includes testing backwash cycle, checking scanner rotation, and calibrating differential pressure switch.

Semi annual maintenance includes inspecting screen condition, cleaning the suction scanner nozzle, and checking motor gearbox grease. Annually inspect seal condition and replace O rings if needed. Keep a log of backwash frequency and duration; increasing frequency indicates worsening water quality and may call for upstream treatment.

The controller stores backwash history with time stamp and duration, allowing maintenance staff to track filter performance trends. An increasing backwash frequency indicates worsening incoming water quality and may call for upstream treatment. The Modbus output exposes filter status, differential pressure, and backwash cycle count to the BMS, enabling predictive maintenance. A manual test button on the controller allows on demand backwash for commissioning. The unit can be supplied with a duplex twin filter arrangement that provides 100 percent duty, allowing one filter to be serviced while the other continues filtration.

Price

From $1,650 per unit. Contact KITOZER for larger sizes and duplex filter configurations.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart