ToggleProduct Overview
The KITOZER 15000 cubic meters per hour axial flow fan is used as the positive pressure supply fan for stairwells and front rooms in high-rise buildings, maintaining a slight overpressure of 25 to 30 Pascals to keep smoke out of evacuation paths during a fire. The fan is rated for continuous operation at 280 degrees Celsius for 30 minutes, satisfying the fire smoke control requirements of GB 51251. The galvanized steel housing and aluminum impeller combine light weight with corrosion resistance, and the motor is mounted outside the airflow stream for easier maintenance.
During a fire, hot smoke rises and spreads along ceilings, threatening evacuation routes. The pressurization fan blows fresh air into the stairwell, keeping the stairwell pressure 25 to 30 Pascals higher than the adjacent corridor. This pressure difference ensures that when a stairwell door opens, air flows out into the corridor rather than smoke flowing in. The fan starts automatically when the fire alarm panel detects smoke on any floor, and it runs until firefighters shut it down. The 280 degrees Celsius rating ensures the fan survives hot smoke for the 30 minutes needed for evacuation.
Technical Specifications
Air flow 15000 m3/h, static pressure 600 Pa, motor power 4 kW, speed 1450 rpm, three phase 380V, impeller diameter 560 mm, housing galvanized steel 2 mm, impeller aluminum alloy, transmission belt drive, noise level 78 dB(A) at 1.5 m, mounting horizontal or vertical, connection spigot DN630, thermal rating 280 degrees Celsius 30 minutes, IP55 motor, Class F insulation, CCCF certified, GB 15930. Weight 95 kg.
The housing is fabricated from 2 mm galvanized steel, with rolled flanges at both ends for duct connection. The impeller is six-blade aluminum alloy, dynamically balanced to grade G6.3. The belt drive uses two SPB belts, with the motor mounted on an adjustable base for belt tensioning. The motor is a 4 kW IE3 efficiency unit, IP55, Class F, mounted on the outlet side outside the airstream. The fan is rated for 280 degrees Celsius continuous for 30 minutes, which means the housing, impeller, and bearings survive hot smoke exposure. The fan ships with a factory performance curve and a CCCF certificate.
Application Scenarios
This fan supplies fresh air to enclosed stairwells, smoke-proof front rooms, and elevator lobbies in office towers, hotels, hospitals, shopping malls, and residential buildings above 50 meters. It starts automatically when the fire alarm panel detects smoke on any floor, and the variable inlet vane or bypass damper adjusts airflow to maintain overpressure as stairwell doors open. KITOZER also supplies matching smoke exhaust fans for the ceiling cavity and car park, and the complete smoke control ductwork and damper package.
For a 100 meter office tower, two fans are installed on the roof, one for the main stairwell and one for the front room. For a hospital, additional fans supply the emergency stairwells on each wing. For an underground shopping mall, fans supply the entrance stairwells to prevent smoke from entering from the mall. KITOZER offers fans in capacities from 5000 m3/h to 60000 m3/h, and pressure ratings up to 1500 Pa. The fans can be configured for roof mounting, wall mounting, or ducted installation.
Key Advantages
The 280 degrees Celsius rating means the fan continues running even if hot smoke is drawn into the shaft, which is essential for protecting evacuation paths. The belt drive isolates the motor from the hot airstream, extending motor life and allowing easy sheave changes. The aluminum impeller is lightweight and dynamically balanced, reducing vibration on the roof support structure. KITOZER provides factory performance test certificates for airflow and pressure, so the commissioning engineer can verify the installed system against design without a full airflow test.
The galvanized housing resists corrosion in the humid roof environment, and the aluminum impeller does not rust even if condensate forms inside. The belt drive allows easy speed changes by swapping sheaves, so the fan can be tuned on site. The IP55 motor survives rain and dust on the roof. KITOZER provides a 2-year warranty on the fan and a 1-year warranty on the motor. Spare belts and bearings are kept in stock in Guangzhou for next-day dispatch.
Installation and Maintenance Recommendations
Mount the fan on spring isolators on the roof or mechanical floor, and connect the duct with flexible canvas connectors to avoid transmitting vibration. Keep fan access panels facing the maintenance walkway. Inspect belt tension quarterly and replace belts every 2 years. Lubricate motor bearings annually, and verify the fire alarm start circuit annually by activating the fan from the fire control room. Record current draw and airflow pressure at each service visit, and compare against the factory curve to detect impeller fouling.
Because the fan sits on the roof, install a bird screen on the inlet to prevent birds from nesting. Keep a weather hood on the outlet to stop rain entering the duct. Check the flexible canvas connectors annually for cracks, and replace if they tear. Test the fan monthly by running it manually from the local switch, and record the running current. KITOZER recommends a 5-year overhaul that includes replacing bearings, belts, and inspecting the impeller for soot buildup. After any fire smoke exposure, the impeller and housing must be cleaned before the fan returns to service.
Price
From $880 per fan. Contact +86 13922289957 for pressurization fan pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com