The KITOZER DN250 hydraulic separator, also called a low loss header or manifold, decouples primary and secondary water loops in chilled water and heating systems. It eliminates hydraulic interference between source pumps and load pumps, stabilizes differential pressure across air handling units, and provides integrated air and dirt separation. This makes it a critical component in variable volume secondary systems where multiple pumps and multiple loads operate independently.
Without a hydraulic separator, changes in flow on one loop cause pressure fluctuations on the other. When a valve closes on the load side, the source pump sees a sudden flow reduction and may dead head or short cycle. The separator provides a large volume vessel where primary and secondary flows can differ without pressure ripple, allowing each pump to operate at its own best efficiency point.
Table of Contents
ToggleProduct Overview
KITOZER hydraulic separators are vertical cylindrical steel vessels with four side connections: primary supply and return, and secondary supply and return. An internal baffle plate slows water velocity below 0.1 m per s, allowing air bubbles to rise to the top automatic air vent and dirt particles to settle at the bottom drain. The vessel is insulated with 20 mm rubber foam and clad in aluminum for indoor installation. Pressure gauge ports and temperature wells are factory installed for monitoring.
The vessel is hydrostatically tested at 1.5 times working pressure before shipment. Flanged connections comply with PN16 standard. The internal epoxy coating protects against corrosion in closed water loops. Optional magnetic dirt separator insert captures ferrous particles that a standard dirt pocket would miss. The separator can be supplied with paint colour matching the plant room aesthetic.
Technical Specifications
Nominal diameter DN250, vessel diameter 400 mm. Working pressure 10 bar. Design temperature 120 C. Maximum flow 250 m3 per h. Connections: primary DN150, secondary DN150, air vent DN20, drain DN25. Flange standard PN16. Insulation thickness 20 mm. Weight 180 kg. Shell material Q235B carbon steel, internal epoxy coating. CE and PED certified, 3 year warranty.
Application Scenarios
Install the hydraulic separator between chiller primary pumps and secondary distribution pumps in commercial HVAC plants. It is also used between heat pump chillers and fan coil loops, between boilers and heating circuits, and in district heating substations. When multiple chillers or multiple boilers share a plant, the separator allows each source pump to run at its own flow rate without affecting the load side. This is essential when primary and secondary flows do not match, which is common in variable flow systems.
In small plants where only one fixed speed primary pump and one variable speed secondary pump exist, the separator prevents the secondary VFD from fighting the primary pump. In larger plants with three or four chillers, the separator acts as a common header that allows any combination of chillers to run without hydraulically affecting the others. It is also used in geothermal heat pump loops to separate ground side pumps from building side pumps.
Advantages and Features
By decoupling loops, the separator prevents short cycling of chillers caused by variable secondary flow. Integrated air and dirt separation improves heat exchanger efficiency and protects control valves from debris. The vertical orientation saves floor space. Flanged connections simplify installation and removal for cleaning. The vessel can be supplied with stainless steel 304 or 316 construction for potable water or corrosive loops. Optional magnetic dirt separator insert captures ferrous particles extending filter service intervals.
Compared with separate air separator, dirt separator, and low loss header, the combined vessel saves three flanged connections and significant floor space. The baffle plate design keeps water velocity low enough for air release but high enough to prevent stagnant dead zones. The automatic air vent at the highest point removes accumulated air during system fill and operation.
Installation and Maintenance
Mount the vessel vertically on the plant floor with the air vent at the highest point. Ensure the primary and secondary piping orientation matches factory marking. Flush the system before commissioning. Vent air during fill. Open the bottom drain quarterly to flush settled dirt. Inspect air vent function annually. Check pressure gauge readings to confirm low pressure drop across the separator; abnormal pressure rise indicates blockage requiring service.
Keep the insulation intact to prevent condensation on cold chilled water vessels. The automatic air vent may need replacement every 5 years if it starts weeping. The magnetic insert, if fitted, should be cleaned quarterly. No other regular maintenance is required. The vessel itself should last the life of the building.
The hydraulic separator can be sized to hold 5 to 10 percent of loop volume for thermal buffering, stabilizing return water temperature during chiller cycling. For larger plants, the separator is supplied as part of a pre piped pump skid with primary and secondary pumps, valves, and gauges. This packaged approach reduces on site piping and commissioning time. The vessel is designed to PED 2014/68/EU pressure equipment directive and can be CE marked as a pressure vessel.
Price
From $860 per unit. Contact KITOZER for custom size and pressure rating.