KITOZER STS: 250A Three Phase Static Transfer Switch

Product Overview

The KITOZER 250A three phase static transfer switch is engineered for enterprise data centers, industrial continuous process plants, and large healthcare campuses that require dual utility or generator feeds with absolutely zero-break source switching. The heavy-duty SCR stack assembly is paired with forced-air cooling and redundant temperature monitoring to support continuous 250A duty in 24 by 7 environments. The advanced controller performs high-speed sampling on all three phases of both sources and triggers a transfer within four milliseconds whenever the preferred source moves outside its programmable envelope. A full maintenance bypass, a metering section, and a redundant control power supply round out the unit into a complete switchboard-ready assembly that can be dropped into a low voltage room without additional engineering.

Technical Specifications

Rated current is 250A continuous at 40 degrees Celsius ambient, three phase four wire 400V line-to-line nominal, 50 Hz or 60 Hz selectable. Short time withstand is 10 kA for one second, backed by current-limiting semiconductor fuses on each SCR branch. Transfer time is less than 4 milliseconds break-before-make. Source sensing is true RMS on all six phases, with independently adjustable under voltage, over voltage, under frequency, and over frequency thresholds per source. The controller includes phase angle measurement and will inhibit transfer if the two sources are not synchronized within a configurable angle window, typically 10 to 20 degrees, preventing circulating currents. Front panel color touchscreen displays source and load voltage, current, power, power factor, energy, SCR temperature, fan status, and a graphical event timeline. Communication includes dual Ethernet ports for Modbus TCP and SNMP v3, isolated RS485 Modbus RTU, and eight Form C alarm relays. Cooling is forced air with two redundant fans; if one fan fails the second carries the full load and an alarm is raised. Control power is dual sourced from the two input lines with automatic internal switchover. Enclosure is floor standing IP32 with bottom cable entry. CE, IEC 60947, and tested to relevant seismic and EMC standards.

Applications

The 250A STS is typically installed in the main power path of medium data centers serving 200 to 400 server racks, in semiconductor fabrication plants, in automotive painting shops, in pharmaceutical cold chain manufacturing, in large hospital operating room electrical panels, and in airport baggage handling systems. It is also used upstream of 200 kVA to 300 kVA UPS systems where the customer wants to avoid single points of failure in the UPS input feed. Generator paralleling switchgear integration is supported through hardwired permissive signals and a Modbus TCP point list that can be matched to the plant SCADA tag library.

Advantages and Features

The KITOZER 250A STS provides sub-cycle transfer regardless of load type, including highly nonlinear rectifier loads that can cause mechanical ATS contacts to chatter or weld. The redundant cooling fan arrangement ensures that a single fan failure does not require load shutdown. The controller stores the last 2000 events with timestamp, voltage and current waveform snapshots, and SCR temperature trend data, giving electrical engineers deep visibility into power quality events. A built-in test mode allows the operator to simulate a source failure and verify transfer behavior without actually disconnecting the load. The unit can be paralleled with additional STS cabinets through a synchronization link, enabling higher current systems for very large data halls. The web interface supports role-based access control and audit logging, which helps facilities meet internal security and compliance review requirements. Because the STS is a factory-tested assembly, field installation time is reduced to cable termination and commissioning rather than on-site wiring of discrete components.

Installation and Maintenance Recommendations

Position the cabinet on a level concrete floor or on an equipment plinth, and anchor it according to the factory drawing. Maintain at least one meter clearance in front for door opening and at least 500 millimeters clearance at the rear for cable work. Use copper busbar or flexible braids rated for 250A continuous and short-circuit withstand. Torque all bolted connections to the values specified on the cabinet nameplate and re-torque after the first 500 hours of operation. Commissioning should include insulation resistance testing on all power circuits, phase rotation verification on both sources, a full load bank transfer test, and a communication integration test with the DCIM or SCADA system. Preventive maintenance on a semiannual schedule includes checking fan airflow, cleaning filters, inspecting SCR connections, and reviewing the event log. The SCR modules are designed for field replacement in under 30 minutes using the factory-supplied spares kit. KITOZER recommends keeping one spare SCR module and one spare control board on site for critical installations.

Price

From $9,480 per piece. Contact the KITOZER factory for detailed quotation, site-specific engineering drawings, and lead time for 250A class static transfer switches.