Table of Contents
ToggleProduct Overview
The KITOZER 108 cell UPS battery monitor is a high-capacity battery string monitoring system designed for large UPS battery rooms in enterprise data centers and telecom central offices. The system tracks the voltage, internal resistance, and temperature of up to 108 individual cells in a single string, and it can scale to multiple strings through additional controller units linked on the same Modbus or Ethernet network. By providing continuous visibility into every cell, the system prevents the most common cause of UPS failure, which is a weak or failed cell dragging down the entire string during a utility outage.
Technical Specifications
The main controller supports up to 108 cell voltage channels and 12 temperature channels, expandable to 216 channels with an expansion unit. Cell voltage measurement range is 0 to 3V for 2V cells, with accuracy plus or minus 2 mV. Internal resistance measurement uses the AC injection method at 10 Hz, resolution 0.01 milliohm, accuracy plus or minus 2 percent. Temperature channels use DS18B20 digital sensors, range minus 40 to plus 125 degrees Celsius, accuracy plus or minus 0.5 degree. The controller also measures total string voltage and string charge or discharge current through a Hall effect sensor installed in the battery cabinet main breaker. Communication ports include isolated RS485 Modbus RTU and dual Ethernet ports supporting Modbus TCP, SNMP v3, and a built-in web HMI. Alarm thresholds are programmable per cell for over voltage, under voltage, high resistance, high temperature, and high temperature rate-of-rise. The system provides relay outputs for general alarm, cell alarm, and string alarm. Power supply is universal 85V to 265V AC or DC. Mounting is on a 35 mm DIN rail inside the battery cabinet or in the adjacent monitoring cabinet. Operating temperature range is 0 to 40 degrees Celsius for the main controller, and minus 10 to plus 55 degrees Celsius for the remote sensing modules. CE marked.
Applications
The 108 cell monitor is installed in UPS battery rooms for 200 kVA to 800 kVA UPS systems, in telecom switch-mode power plant battery banks, in solar farm battery energy storage systems, and in large hospital emergency battery systems. It is also used in financial data center battery rooms where compliance requires continuous cell monitoring. The system is suitable for 2V front-access cells, 12V block cells, and lithium-ion battery strings with appropriate expansion modules.
Advantages and Features
The KITOZER 108 cell monitor provides a complete battery health picture without requiring maintenance staff to manually walk the battery rows with a multimeter, which is a laborious task often skipped during busy periods. By trending internal resistance, the system identifies weak cells months before they fail under load, allowing proactive replacement. The per-cell temperature sensors detect hot spots that indicate internal short circuits, which are the leading cause of battery cabinet fires. The web HMI displays a graphical string map with color-coded cell status, so the operator can immediately identify the failing cell. The system also supports scheduled capacity test logging, recording voltage and current during a full discharge so that the UPS engineer can compare actual capacity against nameplate. The Modbus and SNMP integration allows the battery data to be correlated with UPS status in the DCIM platform, giving a single view of power readiness. Installation is modular: sensing modules snap onto the cells and the main controller mounts on the DIN rail, so a large battery room can be commissioned in a day.
Installation and Maintenance Recommendations
Mount the main controller in the battery cabinet or in a nearby monitoring rack, and distribute the remote sensing modules along the string so that each module covers 12 to 24 cells. Attach voltage sense leads with insulated ring terminals to the cell posts, and mount temperature sensors on the negative post of each cell. Install the Hall effect current sensor around the main negative return cable. During commissioning, verify each cell voltage against a calibrated multimeter and confirm that the sum of cell voltages equals the total string voltage reading. Set alarm thresholds according to the battery manufacturer specifications. The system requires no scheduled maintenance, but the sense leads should be inspected annually for corrosion. KITOZER provides a five year warranty on the main controller and a three year warranty on the sensing modules.
Price
From $2,480 per set including main controller, 108 channel sensing harness, and 12 temperature sensors. Contact KITOZER for expansion module pricing and lead time.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com