The KITOZER 32 point temperature and humidity monitoring system tracks environmental conditions across server rooms, network closets, warehouses, cold storage areas, and production floors. The main controller connects up to 32 digital temperature and humidity sensors through a single bus cable, eliminating the need to run separate cable for each sensor. Data is reported over RS485 Modbus RTU or Ethernet Modbus TCP to a central monitoring platform, and local alarms are triggered through relay outputs when temperature or humidity goes outside the configured range. The system is a cost-effective way to ensure that equipment operates within its rated environmental envelope and to catch air conditioning failures early before they cause equipment shutdowns.
Technical Specifications
The main controller supports up to 32 sensor points, each combining temperature and humidity measurement in a single sealed probe. Temperature range is minus 20 to plus 80 degrees Celsius with accuracy plus or minus 0.3 degree at 25 degrees Celsius. Humidity range is 0 to 100 percent relative humidity, non-condensing, with accuracy plus or minus 2 percent at 25 degrees Celsius. The sensor bus uses a single twisted pair, daisy-chained, with maximum total cable length of 1200 meters using standard category cable. The controller provides 8 alarm relay outputs and 8 digital inputs for connecting additional dry contact devices such as smoke detectors, door contacts, and water leak probes. Communication ports include isolated RS485 Modbus RTU and Ethernet Modbus TCP with a built-in web HMI. Power supply is universal 85V to 265V AC or DC, drawing less than 5W. Mounting is on a 35 mm DIN rail or on a wall. Operating temperature range is minus 10 to plus 55 degrees Celsius. CE marked.
Applications
The 32 point system is installed in data center hot and cold aisles, in telecom equipment rooms, in retail stock rooms, in pharmaceutical storage areas, in museum display rooms, in clean production workshops, and in generator rooms. It is also used in remote edge sites where no on-site staff are present, to ensure that the air conditioning and heating are working. In data centers the sensors are typically placed at rack inlet, at rack exhaust, and at the room cold air return. In cold storage applications the sensors are placed in each refrigerated zone. The digital inputs can be connected to existing smoke detectors and door contacts to consolidate environmental and security monitoring on the same platform.
Advantages and Features
The KITOZER 32 point monitor uses a single bus cable for all sensors, which drastically reduces installation cost compared with running separate shielded cable to each point. The digital sensors are individually addressable, so adding or replacing a sensor does not affect the rest of the network. The web HMI shows a floor plan with color-coded sensor icons, and trend graphs for each point are available on demand. The controller stores the last 100,000 data points locally, so even if the central monitoring platform is offline, the data can be retrieved later. Alarm thresholds are programmable per sensor, with both high and low limits and a rate-of-rise alarm. The system supports email and SNMP trap alarms when the Ethernet option is used. The DIN-rail mounting and universal power supply make the controller easy to install in any existing cabinet. The sensors are small enough to mount on a rack post or on a wall with a single screw. Because the bus is digital, sensor readings are not affected by voltage drop or electrical noise on the cable, which is a common problem with analog sensors. The controller also provides a local buzzer alarm and a set of relay outputs that can trigger external audible alarms or send a signal to the building fire panel. The web interface supports multi-level user accounts, so operators can view dashboards while only administrators can change thresholds.
Installation and Maintenance Recommendations
Mount the controller in the equipment rack or on a wall near the room entry. Run the sensor bus cable from the controller to each sensor location in a daisy-chain arrangement, and terminate the last sensor with the jumper plug supplied. Power up the controller and assign each sensor an address through the web HMI or the configuration tool. Set the temperature and humidity thresholds according to the equipment manufacturer specifications, typically 18 to 27 degrees Celsius and 40 to 60 percent relative humidity for data centers. The sensors require no maintenance, but they should be checked annually against a calibrated reference to confirm accuracy. The controller firmware can be upgraded through the web interface. KITOZER provides a three year warranty on the controller and a two year warranty on the sensors.
Price
From $420 per controller including 8 sensors. Additional sensors are $18 each. Contact KITOZER for full system pricing and lead time.