KITOZER
KITOZER

KITOZER Liquid Cooling Pipe: Stainless Steel DN32 For Rows

Product Overview

The KITOZER stainless steel liquid cooling pipe is a pre-cut, pre-bent 316L tubing assembly for row supply and return loops, CDU risers, and manifold headers. Each pipe section is delivered with welded ends, welded flanges, and electropolished internal bore to minimize fouling and pressure drop. The pipe supports 10 bar working pressure and is compatible with water, 25 to 40 percent propylene glycol, and dielectric coolants. Pre-bent elbows and tees reduce on-site welding, shortening installation time from weeks to days. Each section is factory pressure-tested and tagged with a serial number for traceability.

Technical Specifications

Material: 316L stainless steel, seamless, wall thickness 1.5 mm. Sizes: DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100. Design pressure 10 bar, temperature range minus 20 to 120 C. Ends: welded flange PN16 or grooved coupling. Internal bore: electropolished Ra 0.8. Fittings: 90 degree elbow, 45 degree elbow, tee, reducer, cap. Pressure tested at 15 bar for 30 minutes before shipment. KITOZER, CE, 10 year material warranty.

Applications

Stainless steel pipe is used for row-level supply and return loops connecting the CDU to rack manifolds, for primary loop piping between the chiller or dry cooler and the CDU, and for immersion cooling tank feed lines. Typical deployments include HPC data halls, AI training rooms, and industrial liquid cooling skids. Pre-bent sections simplify installation in raised-floor or overhead cable tray environments where on-site welding is restricted.

Key Advantages

316L stainless resists corrosion in long-life glycol loops, eliminating the rust and sediment problems that plague black iron pipe. Electropolished internal bore minimizes fouling and pressure drop over decades. Pre-bent and pre-flanged sections reduce on-site welding, cutting installation labor by up to 60 percent. Factory pressure-tested to 15 bar ensures quality. Standard flange dimensions match industry CDUs and chillers. Traceable serial numbers support audit and maintenance records.

Installation and Maintenance

Route the pipe through raised floor or overhead tray using standard pipe supports every 1.5 m. Connect flanges with PN16 gaskets and stainless bolts. Pressure-test the completed loop at 1.5 times working pressure for 30 minutes before charging with glycol. Monthly: inspect flange joints for weepage and verify pipe support tightness. Quarterly: inspect insulation condition on cold pipes. Annually: inspect flange gaskets and replace any that show compression set. The pipe itself requires no internal maintenance.

Price

From $35 per meter for DN32. Custom bent assemblies quoted on request. Contact +86 13922289957 for project pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart