KITOZER
KITOZER

KITOZER Microgrid Controller For Islanded PV Storage

The KITOZER microgrid controller is an industrial automation platform that coordinates photovoltaic, battery storage, diesel generator, and load devices in grid-tied and islanded microgrids. It maintains stable voltage and frequency when the main grid fails, dispatches generation and storage to match load, and manages generator start-stop logic to minimize fuel consumption. The controller is suitable for remote communities, mining sites, islands, and industrial campuses.

Product Overview

The KITOZER microgrid controller runs on a rugged DIN-rail industrial computer with redundant power supply and galvanically isolated I/O. It monitors switchgear positions, power meters, PCS, PV inverters, and generator controllers over Modbus TCP, IEC 61850, and hardwired signals. Automatic islanding detection triggers a switch to grid-forming battery operation within milliseconds, shedding non-critical loads if necessary to maintain stability.

Technical Specifications

Hardware: ARM quad-core or x86, 4GB RAM, 32GB storage, 2x GbE, 4x RS485, 8x DI, 8x DO, 4x AI. Protocols: Modbus TCP, Modbus RTU, IEC 60870-5-104, IEC 61850 MMS, DNP3. Islanding detection time less than 20ms. Voltage and frequency control droop adjustable. Operating temperature -20 to +60 degrees Celsius. Power supply 24V DC redundant. Web HMI with single-line diagram. Data logging 1 year local. Certifications CE, IEC 61010. KITOZER brand, 3-year hardware warranty.

Applications

This controller is used in islanded microgrids on islands and remote villages, mining and construction sites with diesel backup, military and critical infrastructure campuses, hospitals and data centers with CHP and storage, and rural electrification projects. It supports both grid-parallel peak shaving and fully islanded operation.

Advantages and Features

Seamless islanding transition protects sensitive loads from interruption. Intelligent generator dispatch minimizes runtime and fuel use by maximizing solar and battery contribution. Load shedding stages can be prioritized by criticality, preserving essential services during shortfalls. The controller supports scheduled and demand-based dispatch strategies. A simulation mode allows operators to test scenarios without affecting live equipment. Open protocols avoid vendor lock-in. Event and trend data support post-incident analysis.

Installation and Maintenance

Mount in the main switchgear room on a DIN rail, powered by redundant 24V DC supplies. Connect Ethernet to the microgrid VLAN and serial lines to PCS, inverters, generators, and meters. During commissioning, map all I/O points, verify islanding detection timing, and test generator start-stop logic. Set load shedding thresholds based on actual generation capacity. Maintenance quarterly includes backup of controller configuration, annually includes firmware update and battery test. Keep a spare controller on site for critical sites to minimize replacement time.

Price

From $4,680/controller. Contact +86 13922289957 for microgrid engineering service and project-based licensing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com