KITOZER Free Cooling Chiller 300RT For Data Center

The KITOZER 300RT free cooling chiller combines a screw compressor refrigeration cycle with an integrated air side free cooling coil. In cold or winter months, ambient air directly cools the glycol loop through the free cooling coil, allowing the compressors to unload or shut down entirely. This dramatically reduces data center PUE and operating cost. The unit is purpose built for outdoor installation in temperate and cold climates where outdoor air temperature drops below 10 C for extended periods.

Free cooling works because data centers need cooling year round even when outdoor air is cold. The chiller controller compares outdoor air temperature with return glycol temperature and decides whether to run mechanical cooling, partial free cooling, or full free cooling. The transition is automatic and seamless, with no operator intervention required. This hybrid approach provides the reliability of a chiller with the energy savings of a dry cooler.

Product Overview

The free cooling chiller uses a twin screw compressor with R513A low GWP refrigerant. The free cooling section is a copper tube aluminum fin coil in series with the condenser. A motorized three way valve diverts return glycol water through the free cooling coil when ambient conditions permit. The controller automatically stages between 100 percent mechanical cooling, partial free cooling, and 100 percent free cooling based on ambient and return water temperatures. EC fans modulate to match the required heat rejection.

The unit includes a weatherproof control cabinet with touch screen HMI, fan contactors, and compressor starters. A glycol make up tank with level switch and heater is integrated. The cabinet is rated IP54 for outdoor installation. Refrigerant side safety valves, suction accumulator, and oil return system are factory installed. The unit is pressure tested and run tested before shipment.

Technical Specifications

Mechanical cooling capacity 300 RT (1055 kW). Free cooling capacity up to 900 kW at 0 C ambient with 10 C return glycol. Glycol solution 30 percent ethylene glycol. Evaporator water flow 180 m3 per h. Power supply 380 V 50 Hz. Compressor power 195 kW. Total fan power 15 kW. Operating ambient range minus 25 C to 45 C. Sound level 78 dB(A) at 10 m. Weight 9500 kg. CE certified, 5 year compressor warranty.

Application Scenarios

This chiller is designed for data center central plants, telecom base station cooling, and industrial process cooling in regions with cold winters. It replaces conventional air cooled chillers and provides substantial energy savings during heating seasons. Typical payback period is two to four years depending on local climate and electricity price. It is also suitable for hybrid cooling plants where a dry cooler provides winter free cooling and the chiller handles peak summer load.

In Nordic and northern China climates, free cooling can cover 4000 to 6000 hours per year. In temperate climates, it covers 1500 to 3000 hours. The chiller is also used in district cooling substations where free cooling supplements electric compression on cold days. For edge data centers, the outdoor installed unit saves indoor plant room space.

Advantages and Features

Integrated free cooling eliminates the need for a separate dry cooler and external piping, reducing installation cost and footprint. Automatic staging ensures smooth transition between cooling modes without operator intervention. The EC fans reduce fan energy compared with fixed speed fans. Low ambient operation down to minus 25 C without head pressure control issues. The unit is pre charged and factory tested, with a complete controller and BMS communication ready. Seasonal energy savings can reach 40 percent compared with standard air cooled chillers.

Because the free cooling coil and condenser share the same fan array, the unit is 30 percent smaller than separate chiller plus dry cooler packages. The three way glycol valve ensures that glycol flows through the correct coil based on mode. The controller logs free cooling hours and energy savings for reporting.

Installation and Maintenance

Install the unit on a level concrete pad with enough clearance for air discharge and coil cleaning. Use flexible connections on water pipes. Verify glycol concentration is adequate for the design minimum ambient. Commissioning includes testing three way valve operation, free cooling interlock, and fan VFD response.

Semi annual maintenance includes coil cleaning, refrigerant leak check, and electrical terminal inspection. Inspect glycol quality annually and top up with inhibited glycol as needed. Winterize the unit by verifying heater and drain functions. Keep a log of mode switching events to confirm free cooling hours match local climate expectations.

The unit is supplied with a weatherproof control cabinet, pressure relief valves, and a glycol make up loop. Optional partial heat recovery captures compressor condenser heat to preheat domestic hot water, improving overall plant efficiency. The EC fan array can be speed controlled by outdoor air temperature, so in shoulder seasons the fans run at reduced speed. The BMS interface allows remote monitoring of operating mode, compressor runtime, and energy savings calculated against a reference mechanical only chiller.

Price

From $38,500 per unit. Contact KITOZER for climate specific energy saving analysis.