Table of Contents
ToggleProduct Overview
The KITOZER DN12 no-spill quick disconnect coupling is a brass nickel-plated push-to-connect fitting designed for cold plate drop hoses, rack manifold ports, and CDU secondary loop connections. The coupling uses a double-flat-face poppet that seals both sides the moment the two halves separate, eliminating coolant spill during server removal or rack maintenance. DN12 is the standard drop-port size for direct-to-chip cold plates serving single CPU or GPU packages, and the coupling supports flow rates up to 30 L per minute at 1.5 bar pressure drop. Each coupling is factory leak-tested to 10 bar before shipment.
The coupling body is machined from brass CW617N and nickel-plated for corrosion resistance in glycol loops. The double flat-face poppet uses EPDM seals that close automatically on disconnect, keeping spillage below 0.05 mL. A push-to-connect lock ring provides positive engagement with an audible click, preventing accidental separation during server slides. The barb end accepts DN12 EPDM braided hose, secured with a stainless steel clamp. Male and female halves are sold as a matched pair and are interchangeable with industry-standard DR-style no-spill fittings.
Technical Specifications
Body: brass CW617N, nickel-plated, design pressure 10 bar. Valve: double flat-face poppet, EPDM seal. Flow rate up to 30 L per minute at 1.5 bar pressure drop. Temperature range: minus 20 to 90 C. Connection: barb for DN12 hose, or threaded G1/2. Coupling method: push-to-connect, lock ring, audible click. Spillage on disconnect: less than 0.05 mL. Compatible fluids: water, 25 to 40 percent propylene glycol, dielectric coolant. Life: 10,000 cycles minimum. KITOZER, CE, 3 year warranty on seals, 5 year body warranty.
The coupling is factory leak-tested to 10 bar for each unit. Flow coefficient is rated at the published pressure drop. EPDM seals are compatible with 25 to 40 percent propylene glycol and most dielectric coolants. The lock ring is spring-loaded and provides tactile and audible confirmation of engagement. Replacement seal kits are available separately, allowing O-ring swaps without replacing the entire coupling. Each pair is serialized for traceability.
Applications
DN12 couplings are used on every cold plate drop hose in direct-to-chip racks, on rack manifold drop ports, and on CDU secondary outlet connections. Typical deployments include GPU training clusters, CPU compute racks, high-frequency trading servers, and storage shelves with liquid-cooled drive modules. The coupling also fits small rear-door heat exchanger loops where the drop flow is under 30 L per minute. Pair kits include male and female halves, barb inserts, and stainless clamps.
Common installations include GPU training racks with 8 to 16 GPU nodes, CPU compute racks for HPC, high-frequency trading servers, and storage shelves with liquid-cooled drive backplanes. The coupling also fits small rear-door heat exchanger loops and immersion tank service lines. Pair kits include male and female halves, barb inserts, and stainless clamps, ready for hose assembly on site.
Key Advantages
Double flat-face poppet eliminates spill on disconnect, protecting electronics and the data hall floor. Push-to-connect lock ring provides positive engagement with audible click, preventing accidental separation. Nickel-plated brass resists corrosion in glycol loops. EPDM seals tolerate long-life coolant and repeated thermal cycling. 10,000 cycle life matches rack service intervals. Factory leak-tested to 10 bar ensures quality on every unit. The coupling is interchangeable with industry-standard DR-style no-spill fittings.
Brass nickel-plated body resists corrosion. Double flat-face poppet seals on both sides. Push-to-connect lock ring prevents accidental release. EPDM seals tolerate glycol and thermal cycling. 10,000 cycle life. Interchangeable with DR-style fittings. Factory leak-tested to 10 bar. Replacement seal kits available.
Installation and Maintenance
Push the male half into the female half until the lock ring clicks. To disconnect, retract the lock ring and pull apart. Use a hose barb insert and stainless clamp to attach DN12 EPDM braided hose. After installation, pressure-test the rack loop at 1.5 times working pressure before charging with glycol. Monthly: inspect coupling seats for weepage and verify lock ring engagement. Quarterly: inspect O-rings for distortion. Annually: replace O-rings on couplings that show wear or staining. Replacement takes under one minute per coupling with the loop isolated.
Commissioning includes pressure test at 1.5 times working pressure, leak check at each coupling, and verification of lock ring engagement. After handover, baseline coupling condition at nominal flow. Recommended on-site spares: one O-ring kit, one coupling pair, and one stainless clamp set. O-ring replacement is recommended every three years or on visible distortion.
Typical Configuration
A typical cold plate drop uses one DN12 coupling pair on the supply side and one on the return side, for a total of two pairs per cold plate. A rack with 16 cold plates therefore uses 32 coupling pairs, plus 2 spare pairs on hand. Each pair is clipped to the server chassis or manifold bracket to prevent hose strain. The coupling is also used at the CDU secondary outlet, where two DN12 pairs connect the CDU to the row header. Contact KITOZER for a bill of materials based on rack count and cold plate layout.
Price
From $18 per coupling pair. Contact +86 13922289957 for volume pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com