ToggleProduct Overview
The KITOZER two-phase immersion cooling tank uses a low-boiling-point dielectric fluorinated fluid that boils directly on heated components and condenses on overhead cold coils, returning as liquid to the bath. This phase-change cycle delivers extremely high heat transfer coefficients and supports rack densities up to 100 kW without pumps or cold plates on the IT side. The tank includes condenser coils connected to facility water, a refrigeration-grade sealed lid, pressure relief valve, and fluid-level controller. Two-phase immersion is the most effective liquid cooling method for the highest-power GPU modules and custom accelerator boards where direct cold plates cannot cover every hot surface.
The condenser coils run along the top of the tank, where boiling vapor rises and condenses on the cold coil surface. The condensed fluid drips back into the bath by gravity, creating a closed loop with no IT-side pumps. Because boiling occurs only where heat is generated, components are cooled exactly where they need it, with near-zero temperature lag. The tank is designed to operate at slight positive pressure under the lid, and a pressure relief valve protects against over-pressurization during high-load startup.
Technical Specifications
Tank capacity 150 to 500 L, stainless steel 316L welded, vacuum-rated construction, 0.3 bar design pressure. Fluid: approved two-phase dielectric fluorinated fluid, boiling point 50 to 60 C, latent heat 80 to 100 kJ per kg, zero ozone depletion potential. Condenser coils: stainless steel, DN32 connection to chilled water at 25 to 30 C. Internal racks support up to 30 servers in 1U to 4U form factor. Controls: 7 inch HMI, fluid level, tank pressure, condenser water temperature, vapor temperature, Modbus TCP, alarm relays. Dimensions 1200 x 1100 x 1800 mm for 300 L model, weight empty 320 kg, CE, KITOZER, 5 year tank warranty.
Sensor suite includes fluid level switch, bath temperature at bottom, vapor temperature at top, tank pressure transducer, condenser supply and return temperature, and flow meter on condenser water. The HMI logs 365 days of 1-minute trend data. Alarm categories cover low fluid level, high vapor temperature, high tank pressure, condenser water fault, and communication. The lid is gasketed and bolted, and opens for server insertion with minimal vapor loss. The pressure relief valve is set at 0.35 bar and discharges to a condensate recovery line.
Applications
Two-phase immersion is reserved for the highest-density compute: custom GPU accelerator boards, high-frequency trading servers, quantum control electronics, and specialized defense or research HPC nodes. Typical users include national supercomputing centers, financial colocation trading floors, semiconductor design simulation labs, and aerospace research facilities. The method also suits environments where free cooling with low-temperature water is available, since condenser water can be supplied at temperatures up to 30 C without degrading performance.
Common installations include custom GPU accelerator racks where every surface must be cooled, high-frequency trading servers with sub-millisecond latency requirements, and quantum control electronics that require extremely uniform temperatures. The method also fits semiconductor design simulation labs and aerospace research facilities where rack density exceeds 100 kW. Because condenser water can be supplied at up to 30 C, the system supports free cooling for most of the year in temperate climates.
Key Advantages
Phase-change heat transfer removes heat at the source with zero temperature lag, allowing components to run closer to their rated thermal limits. No IT-side pumps, no cold plates, no flexible hoses, and no rack power distribution to the cooling loop. The sealed tank prevents fluid emission, and the pressure relief valve protects against over-pressurization. The condenser uses low-grade facility water, enabling free cooling for most of the year. Hardware life extends because components are protected from oxygen, dust, and humidity.
Gravity-return condensate eliminates IT-side moving parts, improving reliability. Fluorinated fluid has zero ozone depletion potential and is recyclable. The tank accepts custom accelerator boards that do not fit standard cold plate designs. Condenser water at up to 30 C enables free cooling. The sealed, gasketed lid minimizes vapor loss during normal operation. Factory vacuum-tested and leak-checked before shipment.
Installation and Maintenance
Install the tank on a sealed secondary containment tray. Connect condenser water DN32 supply and return, route a 16 A single-phase control feed, and fill with two-phase dielectric fluid to the marked level. Monthly: inspect fluid level, tank pressure, and condenser water temperature. Quarterly: sample fluid for contamination and moisture; top up as needed. Annually: inspect lid gaskets, pressure relief valve, and condenser coil fouling. Server insertion uses the lift frame; because the fluid boils and recondenses, short lid opening causes minimal loss.
Commissioning includes verifying condenser water flow, setting bath temperature setpoint, and exercising pressure relief and alarm logic. After handover, baseline vapor temperature and tank pressure at nominal load. Recommended on-site spares: one lid gasket, one O-ring kit, one pressure relief valve, and one fluid level sensor. Fluid top-up uses the same two-phase fluorinated fluid, and mixing chemistries is not recommended. Recover used fluid through a licensed recycler to avoid environmental release.
Price
From $32,000 per 300 L tank. Contact +86 13922289957 for two-phase immersion system pricing.