KITOZER
KITOZER

KITOZER Thermal Management System For Battery Cabinet

The KITOZER thermal management system keeps lithium battery cells within a narrow temperature band, extending cycle life and preventing thermal runaway. Available as forced-air air conditioning or liquid cooling, the system is built into the battery cabinet or container and controlled by a dedicated controller that reads cell temperatures from the BMS. It is essential for high-energy-density storage operating in hot or cold climates, where even a few degrees of temperature difference can halve battery life.

Product Overview

The KITOZER thermal system includes a sealed air handling unit, a DC or AC inverter-driven compressor, a coolant loop for liquid versions, and redundant fans. It maintains cabinet inlet air at 25 to 35 degrees Celsius regardless of ambient, and heats in winter when cell temperature drops below 5 degrees. The controller communicates with the BMS over CAN and adjusts cooling capacity to actual load, saving energy compared with fixed-speed units.

The air handling unit draws warm air from the top of the battery cabinet, passes it over the evaporator coil, and returns cooled air to the bottom, creating a uniform vertical air flow. The liquid version circulates a water-glycol mixture through cold plates attached to each module, which keeps cell-to-cell temperature difference below 2 degrees. The outdoor condenser can be mounted on the roof or beside the container, depending on space. A built-in condensate evaporator tray removes condensation without external drainage.

Technical Specifications

Cooling capacity 3kW to 12kW per cabinet, 30kW to 120kW per container. Refrigerant R410A or R32. Operating ambient -30 to +55 degrees Celsius. Temperature control range 20 to 35 degrees Celsius, stability plus or minus 2 degrees. Humidity control 40 to 60 percent RH. Power supply 230V single phase for small units, 400V three phase for containers. Communication CAN to BMS, Modbus TCP to EMS. Protection IP54 outdoor. Redundant compressor option. KITOZER brand, 3-year warranty on refrigeration parts.

Applications

This thermal system is used in outdoor battery cabinets for C&I storage, battery containers for grid services, telecom base station batteries, and off-grid microgrids in desert, tropical, or cold climates. It is also used in data center UPS battery rooms where high ambient heat would shorten battery life. In desert sites, the system can include a sunshade and an evaporative pre-cooler to reduce compressor load at peak ambient.

Advantages and Features

Variable-speed inverter compressors match cooling to real heat load, reducing parasitic energy use by up to 30 percent compared with on-off systems. Active cooling and heating allow battery operation across a wide ambient range, preserving rated capacity. Uniform air distribution keeps cell-to-cell temperature difference below 3 degrees, the key factor for long battery life. Redundant cooling loops ensure a fault in one loop does not overheat the battery. The unit supports remote monitoring and alarm via the site EMS. Condensate management and air filtration protect cabinet electronics.

The controller uses the actual BMS cell temperatures, not just the return air temperature, to modulate cooling, which prevents local hot spots. The system can be set to economy mode at night, when ambient is cooler, to save energy. An optional humidifier maintains RH in dry climates, preventing static discharge. The condenser fans are EC type, which are quieter and more efficient than AC fans. The whole unit can be isolated for service without shutting down the battery, thanks to a bypass damper.

Quality and Reliability

Every thermal unit passes a 4-hour cooling capacity test at rated voltage and a refrigerant leak test. The compressor is a recognized brand with a 5-year extended warranty option. The control board is conformal coated. KITOZER provides a commissioning report and a spare parts list. The condenser and evaporator coils are corrosion coated for coastal environments. Spare filters and contactors are stocked at regional service partners. The unit also includes a 24V UPS to keep the controller alive through short mains interruptions, so alarms are never lost. In very hot climates, the condenser can be supplied with a sunshade and a misting pre-cooler to maintain efficiency at 50 degrees ambient. The controller also logs every compressor start and stop, which helps schedule preventive maintenance before a failure occurs.

Installation and Maintenance

Mount the air handling unit on the side or top of the cabinet with clear air intake and discharge paths, away from direct sun. Connect the refrigerant lines by a certified HVAC technician and pressure-test before startup. Set the BMS temperature setpoints and interlocks during commissioning.

Maintenance quarterly includes cleaning the air filter and checking refrigerant sight glass, annually includes checking condenser coils, compressor oil level, and electrical terminals. Keep a spare filter and contactor on site. In dusty environments, shorten filter service intervals to monthly. If a low refrigerant alarm occurs, call a certified technician rather than recharging on site, because the leak must be located first.

Price

From $1,680 per cabinet cooling unit. Contact +86 13922289957 for container-level thermal design and heat load calculation.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top