KITOZER Tower UPS: 10kVA Three Phase Online Double Conversion

KITOZER 10kVA three-phase online double conversion tower UPS is a floor-standing critical power system for small and medium data centers, industrial process rooms, and enterprise IT closets. The unit continuously converts utility AC to DC through an IGBT PFC rectifier and regenerates pure sinusoidal AC through a high-frequency inverter, isolating connected loads from surges, sags, swells, harmonics, and frequency drift. With output power factor 0.9, the system delivers 9kW of real power to modern server and storage loads. The high-frequency transformerless design achieves efficiency above 95 percent, reducing cooling requirements and operating cost.

Product Overview

The unit supports both VRLA and LiFePO4 battery banks. The front door locks to prevent unauthorized access, and the cabinet is designed for front service access.

The unit supports generator interface via dry contacts, signaling the generator to start when battery voltage drops below a threshold. This enables seamless integration with site backup power systems.

The 10kVA tower cabinet houses rectifier, inverter, battery charger, bypass circuitry, and a generous internal VRLA battery bank in a single compact enclosure. A 7-inch color touchscreen on the front door displays phase voltages, currents, load bar, battery state of charge, and event history. The unit includes a built-in manual maintenance bypass, allowing service technicians to isolate the UPS electronics while the critical load remains powered through the bypass line. Communication options include Modbus TCP, SNMP, Web HMI, USB, RS232, and dry contact relay outputs, enabling integration with building management, DCIM, and remote monitoring platforms. The front door locks to prevent unauthorized access.

The unit supports N+1 parallel of up to 4 units, allowing operators to add redundancy without over-sizing a single system. The parallel communication cable connects units, and active load sharing ensures each unit carries an equal share within 5 percent. External battery cabinets connect via high-current terminals and are sized to site runtime requirements.

Technical Specifications

The unit supports cold start without utility input. The charger current is adjustable for different battery bank capacities.

Rated 10kVA / 9kW. Input 3P+N+PE 380/400VAC, range 320-480VAC, PFC greater than 0.99, input THDi less than 3 percent. Output 3P+N+PE 380/400VAC, line-to-neutral 220/230VAC, regulation plus or minus 1 percent, THDv less than 2 percent linear load. Inverter efficiency 95 percent, ECO mode 98 percent. Internal VRLA 12V 9Ah x 30, runtime 8-12 min full load. External battery cabinets support runtime up to 4 hours. Parallel N+1 up to 4 units. Operating temperature 0-40C, noise less than 60dBA. Dimensions 600 x 800 x 1400mm, weight 320kg. CE, ISO 9001 certified. KITOZER brand, 3 year warranty.

Application Scenarios

In colocation facilities, the unit provides tenant-level power protection. The parallel N+1 configuration ensures continuous operation during UPS service.

In broadcast transmission hubs, the unit protects playout servers and transmission equipment. The online double conversion topology ensures zero interruption during utility disturbances.

In university research clusters, the unit protects HPC nodes and storage networks. The high efficiency reduces cooling cost.

This tower UPS is commonly specified for medium enterprise server rooms, manufacturing execution systems, hospital imaging departments, broadcast transmission racks, and government data closets. When paired with external battery cabinets, it bridges the 10-30 second gap between utility failure and generator pickup, eliminating any perceived outage. Parallel N+1 configurations are used in healthcare IT, financial back offices, and cloud point-of-presence racks where a single point of failure is unacceptable. The unit is also suitable for small data center colocation facilities.

Advantages and Features

The unit supports remote firmware upgrade via Web HMI. The event log stores the last 1000 alarms for post-incident analysis.

The ECO mode achieves 98 percent efficiency for sites with stable mains, reducing electricity cost while still providing online protection when disturbances occur.

The touchscreen provides real-time power quality data including THD and power factor. The unit supports scheduled battery testing.

Three-phase input and output match standard data center distribution. Low input THDi eliminates upstream harmonic filters. High efficiency reduces cooling and electricity cost. Built-in maintenance bypass enables live service. Parallel N+1 supports modular growth. The color touchscreen and comprehensive communication protocol set simplify commissioning and remote monitoring. The unit supports remote firmware upgrade via Web HMI.

Installation and Maintenance Advice

Keep a log of all maintenance activities. Schedule annual thermographic inspection of terminals. Keep spare fuses on site.

Keep spare batteries on site matching the installed string. Document all configuration changes in the site runbook.

Verify floor load rating and vibration isolation. Use dedicated input and output breakers per local code. Confirm phase rotation before energizing. Size external battery cables for less than 1 percent voltage drop. Configure NTP and alarm recipients during commissioning. Inspect DC terminals annually. Replace batteries every 4-5 years. Keep a log of all maintenance activities for lifecycle planning.