KITOZER 2kVA rack online double conversion UPS delivers conditioned, uninterruptible power for small business server racks containing 1U and 2U servers, SAN storage, and network switching gear. The unit is built around a high-frequency PWM rectifier and IGBT inverter that together produce a pure sine wave output with less than 3 percent total harmonic voltage distortion. This makes it safe for all sensitive electronic loads including active PFC power supplies found in modern servers. The online topology continuously conditions power, so even brief utility disturbances do not reach the connected load.
Table of Contents
ToggleProduct Overview
The unit supports both 110V and 230V output configurations via firmware setting, making it suitable for international deployments. The smart slot accepts SNMP, Modbus, or dry-contact cards, allowing customization for each site.
Housed in a 3U rack-mountable chassis, the 2kVA UPS converts between rack and tower orientation in minutes using included slide rails and support stands. A large graphical LCD on the front panel displays input voltage, output voltage, load percentage, battery state of charge, internal temperature, and event history. The unit ships with USB and RS232 connections, plus a smart slot for an optional SNMP/Modbus TCP card. An isolated outlet group supports sequential shutdown of non-critical loads first, preserving battery runtime for critical servers. An integrated maintenance bypass is optional and recommended for installations where planned servicing of the UPS cannot interrupt the load. The front panel includes lockable doors to prevent unauthorized configuration changes.
Technical Specifications
The unit supports cold start operation without utility input. The charger current is adjustable from 1A to 10A for external battery cabinets. Audible alarm can be muted via front panel.
Rated 2kVA / 1.8kW, output power factor 0.9. Input 220-240VAC, range 110-300VAC, power factor correction greater than 0.99. Output 230VAC, regulation plus or minus 1 percent, THDv less than 3 percent linear load. Inverter efficiency 93 percent, ECO mode 98 percent. Internal VRLA 12V 9Ah x 4, standard backup 6-10 minutes at full load. Recharge to 90 percent in 4 hours. Battery test automatic every 7 days. Operating temperature 0-40C, noise less than 50dBA. Dimensions 438 x 530 x 132mm (3U), weight 32kg. Output sockets 8 x IEC C13. CE, ISO 9001 certified. KITOZER, 3 year warranty, 2 year battery warranty.
Application Scenarios
In educational environments, the unit protects computer lab servers and network switches. The tower option allows deployment in classrooms without server racks.
In manufacturing environments, the unit protects PLC controllers, HMI panels, and industrial communication switches. The tower conversion option allows deployment in production line control rooms without rack mounting.
Typical deployments include small data centers with 3-5 rack servers, virtualization hosts, storage arrays, and core network switches. The unit also protects medical imaging peripherals, industrial SCADA workstations, broadcast studio editing bays, and retail data consolidation racks. When paired with KITOZER external battery cabinets, runtime can extend to 30 minutes or longer for orderly shutdown or generator bridging. The tower conversion option makes the unit suitable for under-desk or floor-standing installations in small offices that do not have a server rack. The unit is also commonly used in small manufacturing lines protecting PLC controllers and HMI panels.
Advantages and Features
The unit supports scheduled battery testing during off-peak hours, and the event log stores the last 500 alarms. The ECO mode automatically switches to online double conversion when a disturbance is detected, balancing efficiency and protection.
True online double conversion ensures zero transfer time even during long brownouts. Active input power factor correction reduces upstream current distortion and lowers utility demand charges. The intelligent battery management system compensates charging voltage for temperature and runs periodic capacity tests, doubling battery life compared with uncontrolled chargers. Hot-swappable battery packs mean battery replacement can be performed live without opening the rack power distribution. The ECO mode achieves 98 percent efficiency for sites with stable mains, reducing electricity cost while still providing online protection when disturbances occur. The SNMP card enables remote monitoring and email alerts.
Installation and Maintenance Advice
Keep spare batteries on site matching the installed string. Document all configuration changes in the site runbook. Verify the shutdown software triggers graceful server shutdown before battery low-voltage cutoff.
Mount the UPS on reinforced rack rails rated for at least 50kg. Keep clearances of 50mm on each side and 100mm at the rear for airflow. Use appropriately rated rack PDU to distribute output to loads. Configure the SNMP card with the site NTP server and alert email recipients during commissioning. Perform quarterly visual inspection of fans and filters, annual load bank test, and battery replacement at 3-5 year intervals. Document every battery replacement and firmware update in the on-site maintenance log. Ensure the shutdown software is installed and tested on every connected server before go-live. Keep the front panel ventilation clear.
Price
From $980/pc. Contact +86 13922289957 for 2kVA rack UPS pricing and external battery cabinet combinations.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com