KITOZER Tower UPS: 20kVA Three Phase For Medium Data Center

KITOZER 20kVA three-phase online double conversion tower UPS is engineered for medium data centers, enterprise IT rooms, and industrial critical power systems that require 18kW of clean, uninterrupted three-phase power. The high-frequency IGBT topology continuously conditions utility power, eliminating disturbances while achieving efficiency above 96 percent. Output power factor 0.9 ensures the unit delivers real usable power matching modern server power supply ratings. The transformerless design reduces cabinet size and weight compared with traditional online UPS.

Product Overview

The unit supports both VRLA and LiFePO4 battery banks with CAN communication. The front door locks to prevent unauthorized access.

The unit supports generator interface via dry contacts for automatic startup signaling. The LiFePO4 interface includes CAN communication for cell-level monitoring and state of charge reporting.

The 20kVA cabinet combines rectifier, inverter, charger, bypass, and monitoring in a compact floor-standing enclosure. A 7-inch color touchscreen displays three-phase voltages, currents, kW, kVA, power factor, battery state of charge, and event logs. The unit includes a built-in maintenance bypass and supports N+1 parallel of up to 8 units. Communication includes Modbus TCP, SNMP, Web HMI, and dry contacts. Optional galvanic isolation transformer is available for sensitive loads.

The unit supports both VRLA and LiFePO4 battery banks. The LiFePO4 interface includes CAN communication for cell-level monitoring, enabling longer runtime and deeper discharge capability. The front door locks to prevent unauthorized access, and the cabinet is designed for front service access.

Technical Specifications

The unit supports cold start without utility input. The static bypass capacity is 150 percent for 60 seconds.

Rated 20kVA / 18kW. Input 3P+N+PE 380/400VAC, range 320-480VAC, PFC greater than 0.99, THDi less than 3 percent. Output 3P+N+PE 380/400VAC, regulation plus or minus 1 percent, THDv less than 2 percent. Inverter efficiency 96 percent, ECO 98 percent. External VRLA or LiFePO4 battery bank per runtime. Parallel N+1 up to 8 units. Operating 0-40C, noise less than 65dBA. Dimensions 800 x 1000 x 1800mm, weight 520kg. CE, ISO. KITOZER, 3 year warranty.

Application Scenarios

In healthcare IT, the unit protects medical record servers and imaging systems. Parallel N+1 ensures continuous operation.

In enterprise virtualization clusters, the unit protects VMware and Hyper-V hosts. The N+1 parallel configuration ensures continuous operation during UPS service.

In cloud point-of-presence facilities, the unit protects edge servers and network switches. The parallel N+1 configuration ensures continuous operation.

Typical deployments include medium data centers, enterprise virtualization clusters, hospital IT rooms, and cloud point-of-presence facilities. The unit is also used in manufacturing execution systems, broadcast playout centers, and government secure rooms. When paired with LiFePO4 battery cabinets, it supports 15-30 minute runtime for generator bridging. Parallel N+1 configurations are standard in healthcare and financial services.

Advantages and Features

The touchscreen provides waveform capture for post-event analysis. The unit stores 1000 event logs.

The high efficiency reduces PUE and cooling cost. The unit supports remote firmware upgrade via Web HMI.

The unit supports Modbus TCP integration with DCIM platforms. The Web HMI allows remote configuration from any browser.

Three-phase in and out matches standard data center distribution. Low input THDi avoids harmonic penalties. High efficiency reduces cooling and electricity cost. Parallel N+1 supports modular growth. Built-in maintenance bypass enables live service. LiFePO4 compatibility enables longer life and deeper discharge. The touchscreen HMI simplifies DCIM integration.

Installation and Maintenance Advice

Keep a log of maintenance activities. Inspect DC terminals annually. Replace batteries every 4-5 years.

Keep spare batteries on site. Document all configuration changes. Verify shutdown software triggers graceful server shutdown.

Keep a log of all maintenance activities. Schedule annual thermographic inspection of terminals.

Verify floor load rating. Use dedicated input and output breakers per local code. Confirm phase rotation. Size external battery cables for less than 1 percent voltage drop. Configure NTP and alarm recipients. Inspect DC terminals annually. Replace batteries every 4-5 years. Keep a log of maintenance activities.