KITOZER
KITOZER

KITOZER Microgrid Controller For Islanded PV Storage

The KITOZER microgrid controller is an industrial automation platform that coordinates photovoltaic, battery storage, diesel generator, and load devices in grid-tied and islanded microgrids. It maintains stable voltage and frequency when the main grid fails, dispatches generation and storage to match load, and manages generator start-stop logic to minimize fuel consumption. The controller is suitable for remote communities, mining sites, islands, and industrial campuses that want to reduce diesel fuel cost and increase renewable penetration.

Product Overview

The KITOZER microgrid controller runs on a rugged DIN-rail industrial computer with redundant power supply and galvanically isolated I/O. It monitors switchgear positions, power meters, PCS, PV inverters, and generator controllers over Modbus TCP, IEC 61850, and hardwired signals. Automatic islanding detection triggers a switch to grid-forming battery operation within milliseconds, shedding non-critical loads if necessary to maintain stability.

The controller includes a built-in single-line diagram HMI that shows real-time power flows, breaker positions, and state of charge. Operators can manually override setpoints with a password. The controller logs every event with timestamp, and stores one year of 1-minute interval data. An optional cloud portal aggregates data from multiple microgrid sites, which is useful for operators with several remote installations.

Technical Specifications

Hardware: ARM quad-core or x86, 4GB RAM, 32GB storage, 2x GbE, 4x RS485, 8x DI, 8x DO, 4x AI. Protocols: Modbus TCP, Modbus RTU, IEC 60870-5-104, IEC 61850 MMS, DNP3. Islanding detection time less than 20ms. Voltage and frequency control droop adjustable. Operating temperature -20 to +60 degrees Celsius. Power supply 24V DC redundant. Web HMI with single-line diagram. Data logging 1 year local. Certifications CE, IEC 61010. KITOZER brand, 3-year hardware warranty.

Applications

This controller is used in islanded microgrids on islands and remote villages, mining and construction sites with diesel backup, military and critical infrastructure campuses, hospitals and data centers with CHP and storage, and rural electrification projects. It supports both grid-parallel peak shaving and fully islanded operation. In telecom base stations, it manages solar, battery, and diesel to reduce generator runtime and fuel deliveries.

Advantages and Features

Seamless islanding transition protects sensitive loads from interruption. Intelligent generator dispatch minimizes runtime and fuel use by maximizing solar and battery contribution. Load shedding stages can be prioritized by criticality, preserving essential services during shortfalls. The controller supports scheduled and demand-based dispatch strategies. A simulation mode allows operators to test scenarios without affecting live equipment. Open protocols avoid vendor lock-in. Event and trend data support post-incident analysis.

The controller includes a built-in PV and load forecast, which improves generator scheduling. It can also respond to grid price signals when grid-connected, shifting battery charge to low-price hours and discharge to high-price hours. The HMI is available in multiple languages. An open API allows the owner to connect third-party SCADA. Redundant power supply and optional redundant controller ensure a single hardware failure does not black out the microgrid.

Quality and Reliability

The industrial computer is fanless and rated for 24/7 operation in switchgear rooms. Every I/O channel is factory tested. The controller comes with a pre-loaded project template for common microgrid topologies, which reduces engineering time. KITOZER provides remote commissioning support during the first 30 days. Spare controllers and power supplies are recommended on critical sites. The enclosure is IP30 and DIN-rail mountable, and the operating temperature range covers most switchgear rooms without extra cooling. The software is licensed per controller and includes free minor version updates; major version upgrades are offered at a discount to existing customers. The controller also supports a redundant master configuration, where two units synchronize over a dedicated link and one takes over automatically if the other fails. This is recommended for critical microgrids such as hospitals and island power stations, where a single controller failure must not cause a blackout. The redundant pair synchronizes over a dedicated Ethernet link and performs an automatic switchover in under 50 milliseconds, so even a master failure is completely transparent to connected loads and processes.

Installation and Maintenance

Mount in the main switchgear room on a DIN rail, powered by redundant 24V DC supplies. Connect Ethernet to the microgrid VLAN and serial lines to PCS, inverters, generators, and meters. During commissioning, map all I/O points, verify islanding detection timing, and test generator start-stop logic. Set load shedding thresholds based on actual generation capacity.

Maintenance quarterly includes backup of controller configuration, annually includes firmware update and battery test. Keep a spare controller on site for critical sites to minimize replacement time. KITOZER engineers provide remote support for the first 90 days. The controller logs all operator actions, which is useful for auditing and for training new operators.

Price

From $4,680 per controller. Contact +86 13922289957 for microgrid engineering service and project-based licensing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com