KITOZER Room Precision Air Conditioner 20kW VFD Dual Compressor N+1

Product Overview

KITOZER 20kW variable-frequency room-level precision air conditioner with dual compressors is built for critical data halls that require resilient, energy-efficient cooling across a wide load range. Two independently controlled scroll compressors, one of which is inverter-driven, stage cooling capacity from 5 to 22kW, allowing the unit to match low nighttime loads and peak daytime loads without frequent on-off cycling. The inherent N plus 1 design means that if one compressor faults, the second unit continues to hold room temperature, avoiding the thermal stress that causes IT equipment failures. The cabinet integrates a brazed plate evaporator, EC centrifugal fan, electric reheat, and electrode humidifier. The inverter compressor modulates speed between 30 and 110 percent, while the fixed-speed compressor stages on and off as needed. This combination delivers smooth temperature hold within 1 degree C even when IT load swings by a factor of three over the course of a day. The unit is available in upflow, downflow, and horizontal discharge configurations to suit any room layout, and the cabinet front door can be locked to prevent unauthorized access.

Technical Specifications

Cooling capacity 20kW sensible nominal, staged range 5 to 22kW, airflow 6,000 cubic meters per hour, static pressure up to 200 Pa, two scroll compressors one inverter charged with R410A, supply voltage 380V three phase 50Hz, rated power about 7.5kW, dimensions 1,200 millimeters wide by 1,000 millimeters deep by 2,200 millimeters high, weight about 320kg, G4 plus F9 filtration, electrode humidifier 12kg per hour, electric reheat 6kW, color touch controller with scheduling, Modbus TCP, SNMP, Bacnet IP, HTTP alarm, CE certified, ambient operating range 20 to 45 degrees C. Additional features include electronic expansion valve, inverter DC bus monitoring, compressor rotation control, high/low pressure protection, and leak detection input.

Application Scenarios

The 20kW VFD dual-compressor unit is deployed in mid-size enterprise data centers, financial back-office server rooms, cloud provider edge PoP sites, hospital core IT rooms, and industrial control centers. It is particularly suitable for facilities where load varies significantly between workday and nighttime hours, since the inverter stage avoids the energy waste of oversized fixed-speed units. Two or more units can be linked via the controller for rotation, redundancy, and staged capacity control across the room. It also suits research labs, pharmaceutical cold rooms, and test equipment bays where precise temperature is required 24 hours a day but occupancy patterns change seasonally. In campus IT deployments, the unit is often paired with a generator and UPS to ensure cooling remains online during utility outages. For multimedia production facilities, the stable temperature protects storage arrays and rendering clusters from thermal throttling during long batch jobs. The inverter drive also reduces inrush current during startup, easing stress on backup generator sets and eliminating the voltage dip that can trip sensitive IT equipment.

Advantages and Features

The inverter compressor delivers part-load energy efficiency above 4.5, significantly reducing annual energy bills compared with fixed-speed systems. Staged capacity control eliminates compressor short cycling, extending component life and maintaining tighter temperature stability. The EC fan array provides redundant airflow paths, so a single fan fault does not stop cooling. The controller logs runtime, alarm history, and energy consumption, supporting DCIM integration and energy reporting. Hot-aisle containment integration allows discharge air to be ducted directly into the cold aisle, further improving efficiency. Compressor rotation across linked units balances wear, and the controller automatically isolates a faulty compressor while the backup maintains cooling. The unit also supports optional heat recovery, reusing condenser heat for space heating or domestic hot water in winter. A factory-commissioned test report includes pressure, temperature, and electrical measurements, and the 5-year warranty covers the compressor, inverter drive, and controller. The cabinet is fully recyclable at end of life, and the refrigerant charge can be recovered without special tooling.

Installation and Maintenance Recommendations

Plan a level concrete pad or seismic-isolated base, allow 800 millimeters front service clearance, and route condensate to a floor drain with an air break. Set compressor rotation schedules evenly across linked units to balance runtime. Commission by measuring supply and return temperatures under simulated load to confirm staged operation. Maintain filters every three months, inspect inverter DC bus capacitors annually, clean condenser coils once per year, and verify refrigerant superheat. Keep a spare compressor contactor and filter dryer on hand. Training for site operators on controller navigation and alarm response is recommended. Verify that the inverter harmonic emissions meet local grid requirements, and install a surge protector on the supply side. For facilities in coastal or industrial environments, specify an epoxy-coated condenser coil to resist salt and chemical corrosion. The controller can export hourly energy data in CSV format for utility rebate applications and internal sustainability reporting.

Price

From $8,980 per unit. Contact KITOZER for redundancy layout and factory lead time.