KITOZER Room Precision Air Conditioner 100kW Water Chilled Water Coil N+1

Product Overview

KITOZER 100kW chilled-water room-level precision air handler is designed for large data centers served by a central plant with chillers. Instead of containing refrigerant within each unit, the cabinet uses a chilled-water coil fed by 7/12 degrees C primary water, removing the risk of large refrigerant charges inside the IT space. The unit includes EC plug fans, a humidifier, electric reheat, and a mixing box for outdoor air economizer integration. Water flow is modulated by a motorized control valve under controller supervision, allowing precise capacity matching across a wide load range. This architecture is the standard approach for Tier-3 and Tier-4 data centers where central plant redundancy and free cooling are required. The air handler can be configured as upflow, downflow, or horizontal discharge, and the cabinet is available with or without an integral refrigerant backup circuit. Each unit is pressure-tested at the factory and ships with a certified performance report.

Technical Specifications

Cooling capacity 100kW sensible at 7/12 degrees C chilled water, airflow 30,000 cubic meters per hour, external static pressure 300 Pa, chilled water flow 18 cubic meters per hour, water connection DN80, EC fan motor total 7.5kW, supply voltage 380V three phase, dimensions 2,200 millimeters wide by 1,400 millimeters deep by 2,400 millimeters high, weight about 950kg, G4 plus F9 filtration, humidifier 60kg per hour, reheat 30kW, 3-way modulating valve, color touch controller, Modbus TCP, SNMP, Bacnet IP, CE certified. Additional features include water differential pressure sensors, temperature sensors on supply and return, condensate float switch, and optional mixed-air damper for outdoor air economizer. The coil is available in copper or stainless steel construction depending on water quality, and the cabinet is finished with a durable powder coat suitable for industrial environments.

Application Scenarios

The 100kW chilled-water air handler is deployed in Tier-3 enterprise data centers, colocation halls, and cloud campuses where a central chiller plant provides redundancy and free cooling. It suits retrofit projects replacing older DX systems with water-based distribution. Units are typically installed in a row along the cold aisle, ducted or with open discharge, and can be grouped for N plus 1 redundancy against fan or valve failure. It also suits large trading floors, university data centers, and government data halls where central plant infrastructure already exists. For facilities with warmer water supply, the coil can be oversized to maintain capacity at 12/18 degrees C water, enabling higher free-cooling hours. In hyperscale campuses, multiple 100kW air handlers feed a common cold aisle, and the controller coordinates with the building automation system to reset water temperature based on aggregate load. For healthcare campuses, the unit supports both IT cooling and medical equipment climate control, sharing the same central chiller plant to reduce capital cost. The unit is also suitable for pharmaceutical manufacturing cleanrooms that require precise temperature and humidity control year round.

Advantages and Features

Chilled-water distribution reduces on-site refrigerant charge and simplifies leak response. Central plant free cooling in winter lowers energy use dramatically. EC fans deliver high part-load efficiency and redundant airflow. The modulating 3-way valve provides smooth capacity control down to 10 percent. The controller coordinates with the BMS to optimize water temperature reset based on load, and supports alarm escalation via email or SMS gateway. The cabinet double-wall insulation prevents surface condensation, and the slide-out fan module allows quick replacement without draining the coil. The 5-year warranty covers fans, coil, and controller, and factory pressure test certificates ship with each unit. The unit is available with either a copper or stainless steel water coil depending on water quality, and the mixing box can integrate 10 to 30 percent outdoor air for ventilation requirements. The controller also supports demand-controlled ventilation based on room CO2 sensors, reducing heating and cooling energy when the room is lightly occupied.

Installation and Maintenance Recommendations

Install water strainers, pressure gauges, and temperature sensors on both supply and return pipes. Insulate all water piping to prevent surface condensation. Commission water flow balance across all air handlers using balancing valves. Maintain filters quarterly, inspect valve packing annually, and clean coils with low-pressure water. Verify humidity sensor calibration every two years. Keep a spare actuator and filter set on site. Plan for condensate drain maintenance to avoid blockages. For critical facilities, install a second 3-way valve in parallel for maintenance bypass. The controller logs water temperature and flow data, enabling detection of coil fouling by tracking rising temperature differential over time. For facilities using tower water, install a side-stream filter and monitor water conductivity to prevent scaling. For closed-loop systems, fill with treated water or glycol solution and pressurize the loop with an expansion tank.

Price

From $38,800 per unit. Contact KITOZER for AHU layout and valve selection.