KITOZER Row Level Air Conditioner 30kW In-Rack Cooling For High Density

Product Overview

KITOZER 30kW row-level air conditioner sits directly in the rack row between server cabinets, delivering cooling exactly where heat is generated. This in-row architecture eliminates long hot-air travel paths and allows rack densities to rise from 5kW to 15kW or more without raising room-level airflow. The unit is the same width as a standard rack (600 millimeters) and fits seamlessly into cold-aisle or hot-aisle containment. A front-facing intake draws in hot exhaust air from the rack aisle, while the discharge side blows cold air into the cold aisle, completing a short, efficient cycle. The in-row design is the preferred solution for data centers with mixed density, where a few racks run hot but the rest remain at conventional density. Row-level units avoid overcooling the entire room for a small number of hot racks. The unit ships with mounting brackets compatible with standard 19-inch rack frames, and the front controller is accessible without opening the cold aisle.

Technical Specifications

Cooling capacity 30kW sensible, airflow 9,000 cubic meters per hour, EC plug fan, scroll compressor R410A, supply voltage 380V three phase 50Hz, rated power about 11kW, dimensions 600 millimeters wide by 1,200 millimeters deep by 2,000 millimeters high, weight about 280kg, G4 plus F9 filtration, humidifier 9kg per hour, touch controller on front door, Modbus TCP, SNMP, Bacnet IP, alarm relay, CE certified, front and rear service access. Additional features include electronic expansion valve, high and low pressure switches, condensate float switch, and optional water-cooled condenser for high-density applications. The cabinet is finished in black powder coat to match standard rack aesthetics, and the front door includes a lockable latch.

Application Scenarios

In-row 30kW units are the standard choice for high-density computing clusters, GPU training racks, storage arrays, and edge colocation sites. They are used in hybrid facilities where most racks remain at 5kW but a few clusters run at 10 to 15kW. The row-level approach avoids overcooling the entire room for a few hot racks and supports phased upgrades as density grows. Units can be air-cooled with remote condensers or water-cooled for maximum density. They also suit AI training clusters, VDI workstation farms, and video rendering farms where heat is concentrated in a small number of cabinets. In retail edge locations, the in-row unit fits inside a small equipment room that also houses the security video recorder and network switches, providing targeted cooling without a dedicated precision AC room. For manufacturing plants, the unit protects industrial PC and PLC cabinets that generate concentrated heat near the production line. The in-row design is also popular in media post-production suites where render nodes and storage arrays run at high density.

Advantages and Features

Localized cooling eliminates hot spots and reduces fan energy. Front-door controller gives technicians immediate access without entering the cold aisle. EC fans modulate speed based on aisle temperature, saving energy. The unit shares a common rack footprint, simplifying containment geometry. Multiple units in a row load-share and provide redundancy; if one faults, adjacent units pick up the load. The cabinet is available in black or neutral gray to match standard rack aesthetics. The 5-year warranty covers compressor, fans, and controller, and the front-service design allows filter replacement without tools. The unit is available with either upflow or downflow discharge depending on the containment architecture, and the front door can be locked to prevent unauthorized access. The controller logs aisle temperature, compressor runtime, and filter condition, and can send SNMP traps or email alarms when any parameter drifts outside preset limits. For facilities with mixed air- and water-cooled rows, the controller supports a common management platform. The in-row unit also supports remote start-stop scheduling, allowing facilities teams to power down unused rows during holidays.

Installation and Maintenance Recommendations

Position the in-row unit in the middle of the rack bank for even aisle coverage. Seal gaps between units and containment panels. Connect condensate drain with an air break. Commission aisle temperature sensors and verify fan modulation under load. Maintenance includes quarterly filter replacement, annual condenser cleaning, and bi-annual compressor inspection. Keep spare filters on site. For water-cooled configurations, install quick-disconnect couplings and leak detection sensors. The controller can be linked with adjacent units for group control and runtime balancing. For air-cooled configurations, route the refrigerant lines to a remote condenser mounted on the nearest exterior wall or rooftop, and keep line lengths under 30 meters to avoid capacity loss. In installations where the in-row unit is paired with rear-door heat exchangers, coordinate water flow balancing so that both systems share the loop without pressure conflicts. The unit can be commissioned remotely via the web interface, reducing the need for on-site visits.

Price

From $11,800 per unit. Contact KITOZER for row layout and redundancy calculation.