KITOZER Free Cooling Air Conditioner 20kW For Cold Climate Data Center

Product Overview

KITOZER 20kW free-cooling precision air conditioner combines mechanical refrigeration with an air-side or water-side economizer, allowing the unit to use cold outdoor air to cool the data hall during winter and mild seasons. When outdoor temperature is low enough, the bypass damper or free-cooling coil handles most of the load, and the compressor cycles off or stages down. This dramatically reduces energy use, lowering PUE toward 1.2 or below in temperate climates. The cabinet integrates EC fans, a modulating damper, a scroll compressor, and an intelligent controller that switches between free cooling, mixed mode, and full mechanical cooling automatically. The controller uses outdoor enthalpy or temperature sensors to determine when free cooling is available, and it ramps the dampers and compressors smoothly to avoid abrupt load changes.

Technical Specifications

Mechanical cooling 20kW, free cooling capacity up to 18kW at 0 degrees C outdoor, airflow 6,000 cubic meters per hour, EC fans, scroll compressor R410A, supply voltage 380V three phase 50Hz, free-cooling mode power below 1kW, dimensions 1,200 millimeters wide by 1,000 millimeters deep by 2,200 millimeters high, weight about 380kg, G4 plus F9 filtration, enthalpy or temperature-based damper control, Modbus TCP, SNMP, Bacnet IP, CE certified. Additional features include motorized outdoor air damper with fail-safe closed position, mixed-air temperature sensor, and compressor staging logic.

Application Scenarios

Free-cooling units are deployed in data centers in northern China, northern Europe, and mountain regions where outdoor temperatures are below 10 degrees C for several months each year. They suit colocation halls, edge PoP sites, and enterprise server rooms seeking low PUE. The units can be retrofitted into existing halls or specified for new builds. They also suit telecom transmission shelters, university data rooms, and government computer centers where sustainability targets require reduced energy consumption. In Scandinavian data centers, free-cooling units can operate in economizer mode for 8,000 hours or more per year, nearly eliminating compressor runtime. In mountainous regions, the combination of low outdoor temperature and low humidity makes air-side economization particularly effective. For facilities with nearby lakes or rivers, water-side free cooling can be added to further reduce energy use.

Advantages and Features

Energy savings of 30 to 50 percent annually in suitable climates. Mixed-mode operation ensures no abrupt switching when outdoor temperature crosses thresholds. Filtration protects IT loads from outdoor dust. The controller logs energy data for reporting. Redundant fans and compressors provide reliability comparable to standard precision units. The fail-safe damper closes on power loss, preventing uncontrolled outdoor air from entering the room. The 5-year warranty covers compressor, damper motor, and controller. The enthalpy-based control logic compares outdoor and indoor air energy content, switching to free cooling only when it is actually beneficial in terms of both temperature and humidity. This prevents over-cooling in winter that would cause over-humidification. The controller also supports schedule-based setback, allowing the room to drift to a higher temperature setpoint during unoccupied periods while still maintaining safe operating conditions for IT equipment.

Installation and Maintenance Recommendations

Locate outdoor intake away from exhaust, roads, and pollution sources. Install motorized dampers with fail-safe closed position. Commission free-cooling setpoints against local climate data. Maintain filters more frequently when outdoor air is used. Inspect damper seals annually and clean outdoor intake louvers. Keep spare damper motor on site. For facilities in dusty or pollen-heavy regions, upgrade to MERV 13 filters on the outdoor air intake and shorten replacement intervals. The controller can export free-cooling hours and energy savings for sustainability reports.