KITOZER Power Lightning Arrester 100kA 385V Three Phase For Building Mains

KITOZER power lightning arrester is a Type 1 plus Type 2 combined surge protector installed at the building mains intake to handle both direct lightning partial current impulse (10 by 350 microsecond waveform) and switching surge currents. The 100kA 385V three phase rating is specified for high rise buildings, telecom towers, industrial substations, and data center main switchboards where the incoming supply is exposed to direct lightning through roof down conductors. Using spark gap technology in series with MOV, the arrester passes the high energy direct strike current without overheating, and clamps residual voltage to below 2.5kV. KITOZER supplies the unit in a wall mount or DIN rail cabinet with remote alarm and event counter.

Product Overview

When a building is struck by lightning, a portion of the strike current travels down the down conductor and couples onto the low voltage power lines entering the building. A standard Type 2 MOV SPD cannot absorb this high energy 10 by 350 microsecond impulse and would fail short. The KITOZER Type 1 plus Type 2 arrester uses a spark gap that fires at high impulse voltage, carrying up to 100kA partial current directly to earth, followed by a MOV stage that clamps residual voltage for downstream equipment. The combination ensures both direct strike energy and switching surges are handled in one unit, reducing cabinet space and cost compared with separate Type 1 and Type 2 devices.

Technical Specifications

Type: Class I plus Class II per IEC 61643 part 11. System: 230/400V three phase four wire. Maximum continuous voltage Uc: 385V AC. Partial lightning current Iimp: 25kA per pole (10 by 350 microsecond). Maximum discharge current Imax: 100kA per pole (8 by 20 microsecond). Nominal discharge In: 50kA. Voltage protection level Up: 2.5kV. Response time: less than 100 nanoseconds for spark gap, less than 25ns for MOV. Follow current extinction: built in, no power frequency follow current. Thermal disconnect: per pole, visual indicator. Remote alarm: dry contact 250V 0.5A. Event counter: optional. Mounting: DIN rail or wall cabinet. Wire size: 16 to 50mm2. Standards: IEC 61643 part 11, EN, GB 18802. Operating temperature: minus 40 to plus 85 degrees Celsius. KITOZER, 5 year warranty.

Applications

The KITOZER 100kA arrester is installed at the main low voltage intake of high rise office buildings, hotels, hospitals, shopping malls, and industrial plants. It is mandatory for telecom base station shelters, broadcast transmitter sites, and wind turbine nacelles where lightning exposure is high. In data centers it sits on the main switchboard ahead of UPS input. For photovoltaic farms it protects the AC side at the grid tie inverter. For mining and oil facilities in open exposed terrain it protects the substation incoming feeder. Coordination with downstream Type 2 SPDs in sub distribution boards provides a multi stage protection scheme from building intake to server rack.

Advantages

Combined Type 1 plus Type 2 in one unit saves cabinet space and reduces installation labor. The 100kA Imax rating handles the largest expected indirect surge without failure. Spark gap technology avoids the runaway thermal failure mode that pure MOV devices exhibit after a direct strike. Event counter lets facilities managers quantify lightning activity and schedule maintenance before failure. Remote alarm integration with BMS means failures are detected immediately, not after an outage. Up to 2.5kV Up level is appropriate for distribution cables and switch mode power supplies. KITOZER units carry CE and IEC certification for international project use, and the plug in module design allows fast replacement after a major strike.

Installation and Maintenance

Mount the arrester as close as possible to the main incoming busbar, with earth leads shorter than 0.5m. Connect line, neutral, and earth with 35mm2 minimum copper, using short straight runs and avoiding bends. Install upstream back-up protection gG fuse 125A or SPD specific breaker. Bond the arrester earth terminal to the main earth bar with a dedicated short conductor. After installation, test the remote alarm contact continuity. Inspect quarterly for visual indicators; red means replace module. Download event counter readings annually and record in the electrical log. After any major lightning storm in the area, inspect the arrester even if indicators are green, because energy absorption degrades future capacity. Keep spare modules and a spare complete unit on site for fast replacement.

Price

From $385 per three phase unit 100kA 385V with remote alarm. Event counter option +$45. Contact +86 13922289957 for project quotation and coordination study.