KITOZER signal surge protector is a series connected data line arrester installed on RS485, RS232, 4 to 20mA analog, and digital instrument loops to protect PLC inputs, DCS cards, and transmitters from surge voltage induced by nearby lightning or ground potential difference. The 12V RS485 model clips in line between the controller and field instrument, diverting surge current to the local earth bar while passing the normal communication signal with less than 1pF capacitance. The compact DIN rail or wall mount housing fits inside instrument junction boxes and PLC cabinets. KITOZER supplies variants for 12V, 24V, and 48V loop voltages, with terminal block wiring for fast field installation.
Table of Contents
ToggleProduct Overview
Long signal cables running between field transmitters and control rooms act as antennas for lightning induced surges. Even with good building grounding, a strike on a nearby tree or crane can induce hundreds of volts on a 2 core shielded cable, destroying the PLC analog input card. The KITOZER signal SPD uses a gas discharge tube between line and earth for high energy surge current, followed by a low clamping voltage TVS diode for fast response. The combination blocks both high energy impulses and fast nanosecond spikes, while keeping insertion loss low enough for 1200 baud to 1Mbps RS485 networks. Installation is series in the cable, so no bypass is needed during SPD replacement.
Technical Specifications
Signal type: RS485 A/B, RS422, 2 wire 4 to 20mA loop, switch contact. Rated voltage: 12V DC maximum continuous. Maximum signal current: 200mA. Nominal discharge current In: 5kA (8 by 20). Maximum discharge current Imax: 10kA. Voltage protection level: line to line 18V, line to earth 350V. Response time: less than 1 nanosecond. Capacitance: less than 100pF line to earth, less than 5pF line to line. Insertion loss: less than 0.5dB at 1MHz. Cutoff frequency: up to 10Mbps. Mounting: 35mm DIN rail or wall. Wire size: 0.5 to 2.5mm2. Standards: IEC 61643 part 21, EN. Operating temperature: minus 40 to plus 85 degrees Celsius. KITOZER brand, 5 year warranty.
Applications
The KITOZER RS485 signal SPD protects Modbus RTU networks between PLC and remote IO, between variable frequency drives and speed sensors, between weather stations and data loggers, between CCTV PTZ controllers and cameras, and between solar inverters and string monitoring units. In oil and gas plants it protects 4 to 20mA pressure and temperature transmitter loops in remote wellheads. In water treatment plants it protects RS485 signals from SCADA to remote pump stations. In building automation it protects BMS bus lines running between floors. In telecom sites it protects alarm lines and remote control signals running between shelter and antenna tower.
Advantages
Low capacitance design keeps high speed RS485 and Ethernet signals clean, which is important for Modbus at 1Mbps and for future upgrade to higher baud rates. The series inline mounting means no signal interruption when the SPD is removed for replacement. DIN rail format fits standard PLC cabinets without custom brackets. Gas tube plus TVS combination handles both high energy and fast spikes better than single technology SPDs. Terminal block wiring removes the need for soldering. The small housing fits inside existing junction boxes, so no extra enclosure is needed. KITOZER units are approved for hazardous area installation (intrinsic safety barrier compatible) and carry CE marking.
Installation and Maintenance
Install the SPD as close as possible to the controller card or to the field instrument, whichever is more exposed to surge. Connect incoming field cable to the line terminals, outgoing cable to the equipment terminals, and the earth terminal to the local bonding bar with 1.5mm2 green yellow wire shorter than 0.5m. Observe A and B polarity. After installation, test communication loop continuity and baud rate. Inspect the SPD annually: the visual indicator (if fitted) shows red for failure. After a nearby lightning strike, inspect the SPD even if indicator is green, because gas tube degradation may not be visible. Replace failed units by disconnecting field cable, sliding out the module, and inserting a new one, without interrupting the control loop for more than a few minutes. Keep spare units on site.
Price
From $18 per piece for RS485 12V signal SPD. 24V loop version from $22. Contact +86 13922289957 for bulk instrument protection pricing.