The KITOZER 50kW three-phase EPS is a central emergency power unit for very large buildings and campus-level fire systems. It feeds multiple emergency distribution boards across a facility, backing up fire pumps, smoke control fans, pressurization fans, central emergency lighting, fire elevators, and fire command center equipment. The unit uses a modular inverter design where two 25kW power modules operate in parallel, allowing hot-swap replacement of a faulty module without shutting down the load. This architecture dramatically improves availability for mission-critical fire systems.
Technical Specifications
Rating: 50kVA / 50kW continuous, three phase four wire 380V / 220V. Configuration: two 25kW modular inverters in parallel, N+1 redundancy optional. Overload: 125 percent for 10 minutes, 150 percent for 1 minute, 300 percent inrush for 10 seconds. Input: 380V three phase, PFC greater than 0.95, THDi less than 5 percent. Output: pure sine wave, THD less than 3 percent, voltage regulation plus or minus 1 percent, frequency 50Hz plus or minus 0.5Hz. Battery: 12V 100Ah VRLA, 180 blocks in three strings, standard 90-minute backup. Charger: 100A with temperature compensation. Protection: DC overcurrent, insulation monitoring, AC overvoltage, overload, short circuit, battery low, over-temperature, fan failure. Communication: Modbus TCP, SNMP, Web HMI, 32 dry-contact I/O. Display: 10-inch color HMI. Enclosure IP21 floor standing, three-section cabinet. Compliance GB 17945, CE.
Application Scenarios
The 50kW EPS is specified for airport terminals, railway stations, convention centers, large hospital complexes, university campuses, and high-rise super-tall towers. It typically powers a zone-based emergency distribution network with separate boards for basement pumps, tower-top fans, stairwell pressurization, and command-center loads. It can start two 22kW fire pumps sequentially and carry 20kW of continuous lighting and control load. It is also used as the alternate supply for critical safety systems in semiconductor fabs and pharmaceutical cleanrooms.
Advantages and Features
The modular inverter design means a faulty 25kW module can be pulled out and replaced while the unit continues to carry the load on the remaining module. Battery strings are independently fused and monitored, and weak strings can be isolated without full shutdown. The HMI provides a one-line diagram with per-module load share, per-string current, and per-block voltage trends. Remote monitoring over Ethernet integrates with the building management system and fire alarm panel, giving operators a single view of emergency power readiness.
Installation and Maintenance
Coordinate the cabinet footprint with the electrical room layout: the three-section cabinet is about 1,800mm wide, 800mm deep, and 2,000mm tall, with a 90-minute battery bank weighing about 3,600 kilograms. Use lifting eyes for positioning. Run battery cables in dedicated tray and size them per local code. Commissioning requires a full load bank test, per-module load share verification, and a pump-start demonstration. Maintenance: quarterly visual and terminal check; annual battery conductance, contactor inspection, and fan filter replacement; every five years replace DC capacitors and contactor arc chutes.