KITOZER
KITOZER

KITOZER EPS Emergency Power Supply 80kW Modular Redundancy

Product Overview

The KITOZER 80kW three-phase EPS is a modular, redundant emergency power unit for mission-critical fire systems in very large buildings. Built from four 20kW hot-swappable inverter modules, the unit operates in N+1 or 2N redundancy, so any single module or even a single string of batteries can be isolated for service without dropping the load. The controller synchronizes all modules and balances load share within 5 percent, ensuring even thermal and electrical stress across the power train.

Technical Specifications

Rating: 80kVA / 80kW continuous, three phase four wire 380V / 220V. Configuration: four 20kW modular inverters, N+1 or 2N. Overload: 125 percent for 10 minutes, 150 percent for 1 minute, 300 percent inrush for 10 seconds. Input: 380V three phase, PFC greater than 0.95, THDi less than 5 percent. Output: pure sine wave, THD less than 3 percent, voltage regulation plus or minus 1 percent, frequency 50Hz plus or minus 0.5Hz. Battery: 12V 100Ah VRLA, 320 blocks in four strings, standard 90-minute backup. Charger: 160A with temperature compensation. Protection: DC overcurrent, insulation monitoring, AC overvoltage, overload, short circuit, battery reverse, over-temperature, fan failure, per-module protection. Communication: Modbus TCP, SNMP, Web HMI, 48 dry-contact I/O. Display: 10-inch color HMI. Enclosure IP21 floor standing, five-section cabinet. Compliance GB 17945, CE.

Application Scenarios

The 80kW modular EPS is specified for major hospital complexes, airport terminals, underground rail hubs, large convention centers, and super-tall towers where a single point of failure in the fire power system is unacceptable. Loads include multiple fire pump motors up to 30kW, basement smoke extraction fans up to 45kW, stairwell pressurization fans, central emergency lighting, fire elevator circuits, and fire command center equipment. The N+1 redundancy is particularly valued in healthcare and transport projects where code requires no single-point failure in emergency power.

Advantages and Features

Hot-swap inverter modules reduce mean time to repair to under 30 minutes, and the failed module can be serviced off-line. Battery strings are independently fused and monitored, with per-block voltage sensing. The HMI shows per-module load share, per-string current, and per-block voltage trends on a single screen. Remote monitoring over Ethernet integrates with BMS and fire alarm systems. The unit supports scheduled automatic discharge tests with auto-recharge and PDF report export.

Installation and Maintenance

Plan the electrical room layout carefully: the five-section cabinet is about 2,400mm wide and weighs over 6,000 kilograms with a 90-minute bank. Use dedicated cable tray and confirm floor loading with the structural engineer. Commissioning includes a 100 percent load bank test, per-module load share verification, and a fault-injection test where one module is pulled while the load continues. Maintenance: quarterly visual and terminal torque; annual battery conductance, contactor inspection, and fan filter replacement; every five years replace DC capacitors and contactor arc chutes. Spare modules should be stocked on site for 2N sites.

Price

From $26,800 per unit with N+1 redundancy and 90-minute battery. Contact +86 13922289957 for 2N pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com