KITOZER
KITOZER

KITOZER SVG 200kVar Static Var Generator For Power Factor

Product Overview

The KITOZER SVG-200 static var generator is a three phase voltage source inverter based compensator that dynamically supplies or absorbs reactive power to maintain power factor near unity and stabilize voltage. Unlike traditional capacitor banks, the SVG uses IGBT switching with instant response, making it ideal for welding loads, elevator loads, VFD driven motors, and renewable energy systems where reactive power fluctuates rapidly. The 200 kVar rating compensates a 1000 kVA to 1500 kVA transformer load and eliminates utility penalties for low power factor.

Technical Specifications

Rated capacity 200 kVar, three phase three wire, 400 V, 50 Hz. Response time less than 10 ms. IGBT based voltage source inverter. Power factor correction to 0.99 leading or lagging. Harmonic filtering 2nd to 25th up to rated current. Overload 1.2 times for 1 minute. Switching frequency 8 kHz. Cooling forced air. Enclosure IP20. Control panel touch screen, Modbus TCP, dry contacts. Efficiency 98 percent. Complies with IEC 61000, IEEE 519.

Application Scenarios

SVG units serve welding workshops, elevator groups in high rise buildings, VFD driven conveyor systems, pump stations, renewable energy grid connection, and commercial buildings with large HVAC chillers. Fast response compensates rapidly varying reactive loads that capacitor banks cannot follow. The unit also filters harmonics generated by VFDs and rectifiers, improving power quality. Installation parallel to the main switchboard.

Advantages

Instant response eliminates flicker and voltage swing. Continuous control from inductive to capacitive, no step switching. Built in harmonic filtering reduces THDi. No resonance risk unlike capacitor banks. Modular units parallel for larger capacity. Touch screen and remote monitoring. Low maintenance: no capacitors to replace. Five year warranty.

Installation and Maintenance

Connect in parallel to the 0.4 kV bus through a dedicated breaker. Install current transformer on the main incoming line for load current sensing. Keep 0.8 m clearance for cooling. Commissioning includes setting target power factor, CT ratio, and response gain. Maintenance annually: clean filters, check IGBT fan, verify communication. Every two years: capacitor bank in DC link inspection, fan replacement. Keep room temperature below 40 degrees C.

Price

From $11,500 per piece including control panel, Modbus TCP, and bypass breaker. Larger capacity and IP54 enclosure are optional.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart