KITOZER
KITOZER

KITOZER EPS Emergency Power Supply 100kW Large Building

Product Overview

The KITOZER 100kW three-phase EPS is a heavy-duty central emergency power unit for large commercial and industrial facilities. With 100kW continuous rating and 300 percent inrush handling, it can start a 45kW fire pump motor directly while carrying 40kW of continuous emergency lighting, ventilation, and control loads. The cabinet uses a split architecture with separate inverter, charger, and battery rooms, allowing installation in buildings with restricted service access. The unit is fully programmable and communicates over Modbus TCP and SNMP to the building management system.

Technical Specifications

Rating: 100kVA / 100kW continuous, three phase four wire 380V / 220V. Overload: 125 percent for 10 minutes, 150 percent for 1 minute, 300 percent for 10 seconds. Input: 380V three phase, PFC greater than 0.95, THDi less than 5 percent. Output: pure sine wave, THD less than 3 percent, voltage regulation plus or minus 1 percent, frequency 50Hz plus or minus 0.5Hz. Battery: 12V 100Ah VRLA, 480 blocks in four strings, standard 90-minute backup, extendable to 2 hours or 4 hours. Charger: 200A with temperature compensation. Protection: DC overcurrent, insulation monitoring, AC overvoltage, overload, short circuit, battery reverse, over-temperature, fan failure, ground fault. Communication: Modbus TCP, SNMP, Web HMI, 48 dry-contact I/O. Display: 10-inch color touch HMI with 20,000-event log. Enclosure IP21 floor standing, multi-section. Compliance GB 17945, CE.

Application Scenarios

The 100kW EPS is specified for very large mixed-use complexes, mega-shopping malls, underground transit hubs, hospital main campuses, and industrial plants with high fire hazard. Typical loads include a 45kW fire pump motor, sprinkler and hydrant pump control panels, basement smoke extraction fans up to 55kW, stairwell pressurization fans, central emergency lighting, fire elevator circuits, fire command center, and gas release pre-action systems. It is also used as the dedicated fire-rated alternate power for semiconductor fabs and pharmaceutical cleanrooms.

Advantages and Features

KITOZER 100kW EPS includes parallel redundant inverter options, allowing two 50kW inverter sections to share load and take over if one faults. The battery system uses individually fused strings with per-block voltage and resistance monitoring, and weak strings can be isolated without shutdown. The HMI provides a full one-line diagram with live status of every pump command, feedback contact, and battery string. Remote cloud monitoring optional, giving facility teams a single pane of glass across multiple buildings.

Installation and Maintenance

Coordinate carefully with structural, architectural, and electrical teams: the multi-section cabinet with a 90-minute battery weighs over 9,000 kilograms, and a 4-hour bank exceeds 20,000 kilograms. Use dedicated battery room with controlled temperature and ventilation. Run battery cables in dedicated tray and size them to keep voltage drop below 1 percent at full load. Commissioning includes a 100 percent load bank test for 30 minutes, a live pump-start demonstration, and a fire alarm interface functional test. Maintenance: quarterly visual and terminal torque; annual battery conductance, contactor inspection, and charger calibration; every five years replace fans, DC capacitors, and contactor arc chutes.

Price

From $36,800 per unit with 90-minute battery. Contact +86 13922289957 for runtime and redundancy options.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top