KITOZER
KITOZER

KITOZER Jockey Pump Control Cabinet 5.5kW Pressure Maintenance

Product Overview

The KITOZER 5.5kW jockey pump control cabinet maintains constant pressure in the fire sprinkler and hydrant pipe network between fire events. Small leaks from gasket seepage, test drips, or minor pressure fluctuations would otherwise cause the large main fire pump to start unnecessarily, wasting energy and wearing the pump. The small jockey pump cycles on and off frequently to keep pressure within a narrow band, and only signals the main pump when pressure drops beyond what the jockey pump can handle.

Technical Specifications

Suitable motor: 5.5kW three phase 380V, rated current about 11A. Starting method: direct-on-line. Input: 380V three phase, 50Hz. Pressure control: two pressure switches, one for jockey pump start, one for main pump start. Typical setpoints: jockey start at 0.85MPa, stop at 1.0MPa; main pump start at 0.7MPa. Protection: motor overcurrent, overload inverse time, phase loss, overvoltage, undervoltage, earth fault, dry run. Indicators: HMI showing running, fault, pressure, runtime. Communication: RS485 Modbus. Dry contacts: running, fault, main pump request, ready. Enclosure IP42 wall or floor mount. Compliance GB 27898, GB 50974, CE.

Application Scenarios

The jockey pump control cabinet is installed alongside every main fire pump controller in commercial buildings, industrial plants, parking garages, and warehouses. It controls the small jockey pump mounted on the sprinkler or hydrant header, and sends a dry-contact signal to the main pump controller when pressure drops below the main pump setpoint. It is also used in high-rise buildings to maintain static pressure on upper floors between fire events.

Advantages and Features

KITOZER jockey pump cabinets include a built-in run-limiting timer that alarms if the pump runs continuously for more than a set duration, indicating a major leak that requires the main pump. The HMI displays current pressure, runtime hours, and start count. A manual pushbutton allows local test. The cabinet includes a dry-contact output to the main pump controller and to the fire alarm annunciator. Compact wall-mount housing saves pump room space.

Installation and Maintenance

Mount the cabinet on the wall adjacent to the jockey pump or in the main pump control panel. Mount pressure switches on the discharge header with isolation valves. Commissioning requires setting the jockey start and stop points and the main pump request point, and verifying that a small drip starts only the jockey while a larger drop requests the main pump. Maintenance: quarterly visual, contactor torque, and pressure switch calibration; annual motor insulation test and current sensor calibration; every five years replace contactor contacts.

Price

From $480 per cabinet including 5.5kW DOL starter and dual pressure switch interface. Contact +86 13922289957 for project pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com