The KITOZER emergency lighting controller is the monitoring and command hub for an addressable intelligent evacuation lighting system. Each luminaire and indicator sign on the loop carries a unique address, and the controller continuously polls them for lamp status, battery voltage, and communication health. On a fire alarm, the controller can reconfigure the evacuation direction dynamically, turning on specific signs and dimming others to guide occupants away from the fire zone. This dynamic evacuation is increasingly required for complex buildings such as malls and transit hubs.
Technical Specifications
Capacity: up to 500 addressable points per controller, expandable to 2,000 with loop extenders. Communication: two-wire loop, RS485 or power-line carrier, loop length up to 2,000 meters. Inputs: 8 programmable dry contacts for fire alarm panel integration. Outputs: 8 programmable relay outputs. Display: 10-inch color touch HMI with floor plan graphics. Features: per-luminaire status, fault logging with timestamp, scheduled self-test, dynamic evacuation routing, group control, scheduled on/off. Communication: Modbus TCP, BACnet optional. Power: 220V 50Hz, internal backup battery for 30 minutes of controller operation. Enclosure IP30 desk or wall mount. Compliance GB 17945, CE.
Application Scenarios
The controller is installed in the fire command center or electrical room of large commercial buildings, shopping malls, underground transit stations, hospitals, and convention centers. It manages addressable evacuation signs and emergency luminaires across multiple floors and zones. It integrates with the fire alarm panel so that a detected fire zone automatically triggers dynamic evacuation routing, redirecting occupants away from the affected exits. It also provides a central inspection point for property managers to confirm every luminaire is healthy.
Advantages and Features
KITOZER controllers support graphic floor-plan display, so operators see at a glance which luminaire has a fault and where it is located. The system automatically runs weekly lamp tests and monthly battery tests, generating PDF reports for fire authority audit. Dynamic evacuation logic can be configured per floor, per zone, and per alarm type. Up to 4 controllers can network together for very large campuses. Remote web access allows facility managers to check system status from a mobile device.
Installation and Maintenance
Mount the controller in the fire command center with a UPS-backed power supply. Run loop cabling in fire-rated conduit and keep it separated from high-voltage power. Commissioning requires addressing each luminaire on the loop, uploading floor plans, and configuring evacuation logic. Maintenance: quarterly visual and loop continuity check; annual battery test on the controller itself, firmware update, and full system test; every four years replace controller backup battery.
Price
From $2,480 per controller for 500-point capacity. Contact +86 13922289957 for campus-scale pricing.