KITOZER
KITOZER

KITOZER Earth Ground Resistance Tester Digital 4 Wire 0-2000 Ohm

KITOZER digital earth ground resistance tester is a handheld instrument used to measure the resistance of grounding electrodes, grounding grids, and soil resistivity. The 4 wire model covers measurement range 0 to 2000 ohm, suitable for commissioning and annual testing of building earthing systems, substation earth mats, tower foundations, and lightning protection electrodes. Using the fall of potential method, the tester injects a known current through auxiliary probes and measures the voltage drop to calculate earth resistance. The large LCD shows resistance, voltage, and current simultaneously, and the unit stores 99 test records for later download. KITOZER supplies the tester with auxiliary probes, test leads, carry case, and calibration certificate.

Product Overview

Earth resistance must be measured at commissioning and annually thereafter to verify that grounding electrodes have not corroded, that soil resistivity has not dried out, and that the grid remains within design limits. The KITOZER tester uses a 4 wire method (also called Wenner for soil resistivity) that eliminates test lead resistance from the measurement, giving accurate readings even with long leads. The instrument generates its own test current at 125Hz, avoiding interference from power frequency noise. The clamp-on option (available separately) can measure earth resistance without driving auxiliary probes, ideal for testing individual electrodes in a grid without disconnecting them.

Technical Specifications

Measurement ranges: 0 to 20 ohm, 0 to 200 ohm, 0 to 2000 ohm. Resolution: 0.01 ohm on low range. Accuracy: plus or minus 2 percent of reading plus 3 digits. Test current: 2mA at 125Hz. Test voltage: 50V DC. Method: 3 wire fall of potential, 4 wire soil resistivity. Power: 4 x AA battery, 50 hours continuous. Display: 6000 count LCD with backlight. Memory: 99 records. Interface: USB for download. Protection: IP40. Operating temperature: 0 to 50 degrees Celsius. Dimensions: 200 x 130 x 60mm. Weight: 1.2kg with leads. Standards: IEC 61557 part 5, CE. Accessories: 2 auxiliary probes, 3 leads 5m, 1 lead 20m, carry case, calibration certificate. KITOZER brand, 2 year warranty.

Applications

The KITOZER earth tester is used by electrical contractors to commission new grounding installations, by facility teams to perform annual earth resistance tests in data centers, substations, telecom towers, and industrial plants, and by lightning protection inspectors to verify down conductor to electrode continuity. The 4 wire mode measures soil resistivity for new design of earth grids. It is also used to test step and touch voltage during substation commissioning. Telecom teams test tower footing resistance to ensure below 5 ohm. Solar farm teams test array frame grounding. Safety inspectors use it to verify building earthing compliance with local electrical codes.

Advantages

4 wire method removes lead resistance errors, essential for long leads in large substations. The 125Hz test current rejects power line noise, giving stable readings even near live switchgear. 99 record memory reduces manual note taking. USB download produces professional test reports for clients. Wide 0 to 2000 ohm range covers both low resistance substation grids and high resistivity rocky soil. Backlit LCD works in dark cable pits. Light weight 1.2kg body is carried around site all day. KITOZER tester comes with calibration certificate traceable to national standards, required by inspection codes. The clamp-on accessory option saves time on grid testing without disconnecting electrodes.

Installation and Maintenance

For fall of potential test, drive the current probe 30m away from the electrode under test, and the potential probe 62 percent of that distance (18.6m for 30m). Connect the tester to electrode, potential probe, and current probe per the manual. Press test; the reading is earth resistance. Repeat at 50 percent and 70 percent distance to verify the plateau. For soil resistivity, use equal probe spacing and apply the Wenner formula. After use, wind leads neatly, clean probes, and store in the carry case. Replace battery when low indicator appears. Send for annual calibration. Keep spare fuses and probes. Record each test in the earthing log with date, weather, and reading, to detect seasonal trends.

Available Models and Custom Service

KITOZER stocks the 4 wire earth tester with leads and probes in a carry case for immediate dispatch. Higher range 0 to 2000 ohm models are available, and a clamp-on earth tester without auxiliary probes is quoted for grid testing without disconnection. Insulation resistance tester and loop resistance tester versions are in the same product family. KITOZER can supply a complete electrical test kit including earth tester, insulation tester, and voltage detector for commissioning teams. Each instrument ships with a calibration certificate, and annual calibration service is available from KITOZER laboratory. Factory lead time for standard models is one week, and for custom data logging versions two weeks. KITOZER can also provide on site earth grid commissioning support for new substation projects.

Price

From $285 per digital 4 wire earth resistance tester with leads and probes. Clamp-on accessory from $185. Contact +86 13922289957 for electrical test instrument project pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com