KITOZER EPS Emergency Power Supply 20kW Three Phase Motor Starting

Product Overview

The KITOZER 20kW three-phase EPS emergency power supply is sized to handle the inrush current of direct-on-line started fire pump motors while simultaneously carrying emergency lighting and control loads. Motor-starting duty is the key challenge for fire-rated EPS: standard UPS units trip on 6 times rated motor inrush, but this EPS is over-sized on inverter and transformer to deliver 300 percent overload for one minute, allowing a 7.5kW or 11kW fire pump to start directly without a soft starter. The unit is packaged as a floor-standing fire cabinet suitable for pump rooms and basement electrical rooms.

Working Principle

The inverter runs continuously from the DC bus, which is fed by both the rectifier charger and the battery bank. When the controller receives a fire alarm start signal, it immediately energizes the pump starter contactor. The inverter detects the sudden current step and boosts its DC bus utilization for 10 seconds to ride through the locked-rotor inrush, which can reach 6 times rated motor current. Once the motor accelerates to running speed, the inverter returns to normal regulation. The same process occurs automatically on mains outage, with the battery supplying the DC bus. The controller logs every motor-start event with voltage sag duration and peak current for maintenance review.

Technical Specifications

Rating: 20kVA / 20kW continuous, three phase four wire 380V / 220V. Overload capacity: 125 percent for 10 minutes, 150 percent for 1 minute, 300 percent motor inrush for 10 seconds. Input: 380V three phase, PFC greater than 0.95, THDi less than 5 percent. Output: pure sine wave, THD less than 3 percent, voltage regulation plus or minus 1 percent, frequency 50Hz plus or minus 0.5Hz. Battery: 12V 100Ah VRLA, 60 blocks, standard 90-minute backup at 20kW, extendable. Charger 40A. Protection: output short circuit with electronic trip, reverse battery polarity, fan failure, DC bus soft start. Communication: Modbus TCP, SNMP, 8 dry-contact I/O. Display: 7-inch color HMI with mimic diagram. Enclosure IP21 floor standing, powder coated. Compliance GB 17945, GB 51348, CE.

Application Scenarios

This EPS is typically specified for mid-size commercial and industrial buildings where the fire pump motor must be backed up. Loads include a 7.5kW or 11kW fire pump motor direct-on-line starter, sprinkler pump control panel, hydrant pump control panel, smoke exhaust fans, pressurization fans, and a building-wide emergency lighting bus. It is also used in parking garages, warehouse distribution centers, and mid-rise hotels where a generator is not installed but fire code requires an alternate power source for the pump and egress systems. It is the standard choice when the owner wants a single piece of equipment to cover both pump motor and lighting backup. The cabinet also accepts start signals from pressure switches, fire alarm panels, and local pushbuttons, and it sends running and fault contacts back to the fire annunciator panel for centralized monitoring.

Advantages and Features

The KITOZER 20kW EPS includes a built-in motor-starting profile that boosts inverter voltage for 10 seconds during pump start, preventing the output from sagging under locked-rotor current. The cabinet integrates a main breaker, maintenance bypass, and output distribution sub-breakers for each emergency circuit, reducing field wiring. Battery strings are individually fused and monitored. The HMI displays a one-line diagram with live status of each pump command and feedback contact, giving fire officers a clear view of system readiness. The unit supports scheduled automatic discharge tests with auto-recharge.

Options and Accessories

Optional items include a parallel redundancy kit, an output distribution board with pre-labeled sub-breakers, a galvanic isolation transformer, and an IP54 enclosure. A remote mimic panel for the fire command room is available. Extended runtime cabinets for 2 or 4 hours can be added later. A cloud monitoring gateway pushes pump-start events and battery health to a web dashboard. Custom paint and customer branding are supported.

Installation and Maintenance

Install in a clean, ventilated pump room or electrical room. Ensure the floor can support the cabinet and battery weight, typically 1,100 kilograms. Route battery cables with appropriate cross-section to keep voltage drop below 1 percent during pump start. Commissioning requires a live motor-start test with the actual pump load to confirm inverter voltage sag and duration. Maintenance: quarterly visual, terminal torque, and pump-start test; annual battery conductance and inverter calibration; every five years replace fans and DC capacitors. Keep a logged discharge test every 12 months for fire department audit.

Price

From $5,680 per unit with 90-minute battery and motor-start capability. Contact +86 13922289957 for pump-motor-specific sizing.