KITOZER EPS Emergency Power Supply 30kW Three Phase Extended Runtime

Product Overview

The KITOZER 30kW three-phase EPS emergency power supply is a mid-size central backup unit for high-rise buildings and industrial plants that need to power multiple fire pumps, large ventilation fans, and building-wide emergency lighting during a prolonged mains outage. The modular power-cord design allows the inverter and battery cabinets to be separated, which simplifies installation in buildings with narrow corridors or restricted service elevators. The unit supports motor-start duty and can start a 15kW fire pump directly while simultaneously feeding 10kW of lighting and control loads.

Working Principle

The active front-end rectifier produces a regulated DC bus from three-phase utility and charges the battery bank through a temperature-compensated three-stage charger. The insulated gate bipolar transistor inverter continuously reconstructs a pure sine wave on the output bus, so the load never sees raw utility power. On mains failure, the battery bank takes over the DC bus without interruption, and the controller logs the event. When a pump start command arrives, the inverter boosts its output capacity for 10 seconds to ride through locked-rotor current. On mains return, the charger resumes bulk charging and the unit returns to float. The controller runs weekly self-tests that lightly discharge the battery to confirm capacity.

Technical Specifications

Rating: 30kVA / 30kW continuous, three phase four wire 380V / 220V. Overload: 125 percent for 10 minutes, 150 percent for 1 minute, 300 percent inrush for 10 seconds. Input power factor greater than 0.95, THDi less than 5 percent. Output: pure sine wave, THD less than 3 percent, voltage regulation plus or minus 1 percent, frequency 50Hz plus or minus 0.5Hz. Battery: 12V 120Ah VRLA, 80 blocks in two strings, standard 90-minute backup at 30kW, 2-hour and 4-hour options. Charger 60A with temperature compensation. Protection: DC overcurrent, AC overvoltage, overload, short circuit, battery low, over-temperature, fan failure. Communication: Modbus TCP, SNMP, Web HMI, 16 dry-contact I/O. Display: 7-inch color touch HMI with event log of 10,000 records. Enclosure IP21 floor standing, split battery and inverter cabinets. Compliance GB 17945, CE.

Application Scenarios

The 30kW EPS is specified for super-tall residential towers, large hospital campuses, convention centers, underground rail transfer stations, and manufacturing plants with fire hazard classification. Typical loads include two fire pump motors in the 11kW to 15kW range, sprinkler pump and hydrant pump control panels, basement smoke extraction fans up to 11kW, stairwell pressurization fans, central emergency lighting inverter distribution, fire elevator emergency circuit, and fire telephone exchange. It is also used as the emergency power source for critical process controls in chemical and pharmaceutical facilities where a sudden outage could trigger a safety incident. The unit can be divided into multiple output distribution boards by floor or zone, and the controller supports scheduled group testing so that only one zone is taken off line at a time during maintenance.

Advantages and Features

KITOZER 30kW EPS uses a parallel-redundant inverter architecture option, allowing two 15kW inverter modules to share load and take over if one module faults. The split-cabinet design lets installers place batteries in a dedicated battery room with better temperature control, while the inverter sits in the electrical room. The HMI supports scheduled automatic discharge tests at 30 percent and 60 percent load, with automatic recharge and report generation. Remote monitoring via cloud gateway optional, giving facilities teams visibility into battery state of health across multiple sites. Battery strings are independently fused and monitored.

Options and Accessories

Options include N+1 inverter redundancy, a parallel synchronization kit for up to 4 units, a galvanic isolation transformer, and an IP54 enclosure. A remote mimic panel for the fire command room is available. Extended runtime cabinets for 3 or 4 hours can be added later. A cloud monitoring gateway pushes battery health and pump-start events to a web dashboard. Custom paint, customer branding, and bilingual labels are supported. Seismic bracing kits are available for earthquake-prone regions.

Installation and Maintenance

Coordinate with the structural engineer on floor loading, since a 90-minute battery bank can weigh 1,800 kilograms and a 4-hour bank over 5,000 kilograms. Run battery cables in dedicated cable tray separated from AC power cables to reduce noise. Ensure the battery room ventilation meets local code for VRLA off-gassing. Commissioning must include a full load bank test at 100 percent for 30 minutes and a live pump-start demonstration. Maintenance: quarterly visual and terminal check; annual battery conductance test, contactor inspection, and charger calibration; every five years replace inverter fans, DC bus capacitors, and contactor arc chutes.

Price

From $7,980 per unit with 90-minute battery bank. Extended runtime and redundant inverter options quoted on request. Contact +86 13922289957 for project pricing.