KITOZER
KITOZER

KITOZER Emergency Lighting Controller 500 Addressable Points

Product Overview

The KITOZER emergency lighting controller is the monitoring and command hub for an addressable intelligent evacuation lighting system. Each luminaire and indicator sign on the loop carries a unique address, and the controller continuously polls them for lamp status, battery voltage, and communication health. On a fire alarm, the controller can reconfigure the evacuation direction dynamically, turning on specific signs and dimming others to guide occupants away from the fire zone. This dynamic evacuation is increasingly required for complex buildings such as malls and transit hubs, where a static exit sign might point occupants toward the fire.

Working Principle

The controller communicates with every addressable device on the loop over a two-wire bus, polling each device several times per minute for lamp current, battery voltage, and fault status. When the fire alarm panel sends a zone alarm signal through a dry contact, the controller looks up the programmed evacuation logic for that zone and commands the relevant luminaires and signs to change state. Signs that previously showed an arrow toward the affected exit can be switched to show a blocked indicator or an arrow toward the safe route. The controller logs every state change and every device fault with timestamp, and generates weekly self-test reports.

Technical Specifications

Capacity: up to 500 addressable points per controller, expandable to 2,000 with loop extenders. Communication: two-wire loop, RS485 or power-line carrier, loop length up to 2,000 meters. Inputs: 8 programmable dry contacts for fire alarm panel integration. Outputs: 8 programmable relay outputs. Display: 10-inch color touch HMI with floor plan graphics. Features: per-luminaire status, fault logging with timestamp, scheduled self-test, dynamic evacuation routing, group control, scheduled on/off. Communication: Modbus TCP, BACnet optional. Power: 220V 50Hz, internal backup battery for 30 minutes of controller operation. Enclosure IP30 desk or wall mount. Compliance GB 17945, CE.

Application Scenarios

The controller is installed in the fire command center or electrical room of large commercial buildings, shopping malls, underground transit stations, hospitals, and convention centers. It manages addressable evacuation signs and emergency luminaires across multiple floors and zones. It integrates with the fire alarm panel so that a detected fire zone automatically triggers dynamic evacuation routing, redirecting occupants away from the affected exits. It also provides a central inspection point for property managers to confirm every luminaire is healthy, reducing manual floor-by-floor checks. The controller can also be used as a standalone monitoring point for smaller sites that do not need the full addressable loop.

Advantages and Features

KITOZER controllers support graphic floor-plan display, so operators see at a glance which luminaire has a fault and where it is located. The system automatically runs weekly lamp tests and monthly battery tests, generating PDF reports for fire authority audit. Dynamic evacuation logic can be configured per floor, per zone, and per alarm type. Up to 4 controllers can network together for very large campuses. Remote web access allows facility managers to check system status from a mobile device. The HMI supports multiple languages and password-protected configuration.

Options and Accessories

Optional items include loop extenders for up to 2,000 points, a BACnet communication card for BMS integration, a remote annunciator panel for the fire command room, and a 4-hour controller backup battery. A cloud monitoring gateway pushes device health and alarm events to a web dashboard. Custom floor plan graphics and customer branding are supported. Spare loop cards and power supplies can be stocked on site.

Installation and Maintenance

Mount the controller in the fire command center with a UPS-backed power supply. Run loop cabling in fire-rated conduit and keep it separated from high-voltage power. Commissioning requires addressing each luminaire on the loop, uploading floor plans, and configuring evacuation logic. Maintenance: quarterly visual and loop continuity check; annual battery test on the controller itself, firmware update, and full system test; every four years replace controller backup battery.

Warranty and Factory Testing

Every KITOZER unit undergoes a full-load burn-in test for 4 hours before shipment, with a printed test report covering input voltage, output voltage, transfer time, and protection relay operation. The power electronics carry a 5-year warranty against manufacturing defects, while the battery bank carries a 3-year replacement warranty. Spare parts are available from stock in Guangzhou, and on-site commissioning support can be arranged for large projects.

Delivery and Packaging

The unit is packed in a seaworthy plywood crate with foam cushioning for international shipment. Standard lead time is 15 to 25 working days after order confirmation, depending on battery capacity and options. Shipping can be arranged by sea freight, air freight, or express courier to most destinations. A detailed packing list, user manual, and factory test report are included with every shipment.

Price

From $2,480 per controller for 500-point capacity. Contact +86 13922289957 for campus-scale pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart