The KITOZER non-locating water leak detection rope provides affordable water presence detection along runs up to 100 meters, without the position-reporting electronics of a locating system. When water touches the braid, the controller closes a relay and raises an alarm, telling operators that a leak exists somewhere on the loop. This is sufficient for small rooms, equipment corners, and protection zones where the search area is small and the cost of a locating system is hard to justify.
Table of Contents
ToggleProduct Overview
The rope uses two braided stainless or conductive-polymer cores inside a porous polyurethane jacket. Any water bridge closes the circuit, and the controller detects the change from open to resistive. After the water dries, the rope returns to normal and can be reused indefinitely. The controller offers 1 to 8 zones, each with its own relay and a shared RS485 Modbus bus. LED indicators on the controller show which zone triggered, narrowing the search to one loop rather than the whole site.
The polyurethane jacket is flexible down to minus 20 degrees and UV resistant for roof installations. Unlike porous fabric ropes that swell and stain, the KITOZER jacket wipes clean and does not retain water, which means false alarms from floor cleaning dry out within minutes. The braided cores resist corrosion in wet environments, and the splice connector uses screw terminals so installers join sections with a screwdriver rather than special crimps.
Technical Specifications
Rope: two-core braid, polyurethane jacket, 5 millimeter diameter. Detectable: conductive water-based liquids. Max loop length: 100 meters. Operating temperature: -20 to 60 degrees Celsius. Controller: 1 to 8 zones, 8 relay outputs, RS485 Modbus RTU, 12-24V DC power. Accessories: end cap, splice clip, mounting clip. Certifications: CE, RoHS. Warranty: 2 years controller, 1 year rope.
The supervised controller distinguishes three states: normal open circuit (no water), closed low-resistance (water detected), and open circuit with broken wire (fault). This prevents the classic nuisance where a broken cable is mistaken for a leak. Each relay is SPDT 5A, so it drives a siren or BMS input directly. The RS485 bus runs at 9600 or 19200 baud, and the controller address is set by DIP switch. Power input accepts 12 or 24V DC, matching most building control supplies.
Application Scenarios
Small server rooms lay a single loop around the floor-standing AC unit. Kitchens place the rope under dishwashers and ice machines. Roof gardens run the line across roof drain pans. Basements protect sump pump areas. Retail stockrooms protect inventory storage above water pipes. Because each controller covers up to 8 zones, a typical small site protects several corners with one panel. The low price makes it easy to justify on projects where insurance or audit requires leak detection but budget is tight.
In museum storage, the rope runs under roof drains and around HVAC humidifier lines. In school computer labs, it loops around the window AC unit. In veterinary clinics, it sits under the dental scrub sink. In retail stockrooms, it protects cardboard inventory from a slow pipe drip. Each of these applications needs leak presence, not leak position, and the non-locating rope delivers that at a fraction of the locating system cost.
Key Advantages
The biggest advantage is cost: non-locating rope costs a fraction of a locating system while still catching the leak event. The reusable jacket survives cleaning, humidity, and brief wetting without replacement. Zone grouping on one controller keeps wiring simple. Relay outputs interface with any alarm panel. The polyurethane jacket resists UV and abrasion for roof and basement use. Simple on-off logic means installers can deploy it without training.
Supervised inputs mean a broken cable is reported as a fault, not a leak, which avoids the nuisance-calling cycle that plagues simple 2-wire ropes. The 8-zone controller consolidates up to eight protection loops into one panel, reducing cabinet space. The DIP-switch address and baud rate mean no laptop is needed on site. The rope and controller from the same vendor means one warranty contact, not a finger-pointing exercise between rope maker and panel maker. For projects that later need position reporting, the same controller accepts KITOZER locating cable without replacement, which protects the initial investment.
Installation and Maintenance
Clip the rope to the floor in a continuous loop, leaving a little slack to avoid pulling at splices. Always fit the supplied end cap; an unterminated rope produces a permanent fault. Test each zone by dabbing a wet paper towel and confirming the relay closes. If a false alarm occurs after floor cleaning, wait for the rope to dry; do not replace it. Inspect the jacket annually for cracks and replace sections that show abrasion. Keep spare rope on site for quick repairs.
Price
Rope from $9 per meter, 8-zone controller from $320. Contact +86 13922289957 for bundle pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com