The KITOZER 80dB welded steel plate EMI shielded room is a purpose-built Faraday enclosure designed to isolate sensitive electronic equipment from external electromagnetic interference and to prevent internal radiated emissions from leaking into the surrounding environment. Constructed from double-galvanized or stainless steel plates with continuous mig-welded seams, the room provides a uniform conductive shell that delivers at least 80 dB of attenuation across the 14 kHz to 1 GHz frequency range, with performance extending well into the microwave band. This welded architecture is selected for permanent installations where maximum shielding integrity, long service life, and zero maintenance of panel joints are required. Typical users include defense contractors, broadcast transmitters, industrial automation integrators, and laboratories performing conducted and radiated immunity testing. The room also serves as a stable reference volume in which ambient noise is low enough to reveal weak signals that would otherwise be buried in urban RF background.
Table of Contents
ToggleProduct Overview
The enclosure is assembled from modular steel panels that are site-welded together, eliminating the leakage paths associated with bolted or clipped panel systems. Every seam, corner, and penetration is continuously bonded so that the entire room behaves as a single conductive volume. The interior can be finished with painted or anti-static wall coatings, and the ceiling supports pendant lighting, suspended absorbers, or rack-mounted equipment. The floor is typically raised or sealed depending on whether the room sits on a concrete slab or a structural mezzanine. KITOZER engineers size each room based on the actual footprint, ceiling height, equipment layout, cable penetrations, and ventilation requirements, ensuring that no opening compromises the specified attenuation. A typical project includes a shielded entry vestibule or interlock airlock so that operators can enter and exit without breaching the conductive shell.
Technical Specifications
Standard construction uses 2 mm double-sided galvanized steel plate, with optional 3 mm stainless steel for corrosive or cleanroom environments. Shielding attenuation is rated at 80 dB minimum from 14 kHz to 1 GHz and 60 dB from 1 GHz to 40 GHz, verified per IEEE Std 299. The room accommodates shielded doors with honeycomb vents, filtered power lines, shielded windows, and waveguide panels for HVAC penetrations. Power entry modules provide three-phase 400 V filtered feeds rated from 63 A to 630 A. Signal penetrations use filtered bulkhead plates supporting fiber, copper, coaxial, and pneumatic interfaces. The conductive shell is bonded to a dedicated grounding busbar at less than 2.5 mW impedance to the site earth. Operating temperature range is 10 C to 40 C, with relative humidity below 70 percent non-condensing. Wall loading for suspended equipment is 100 kg per square meter, and ceiling loading is 75 kg per square meter.
Applications
This welded enclosure is deployed as an anechoic or semi-anechoic chamber host, an EMC pre-compliance test room, a TEMPEST countermeasure space, a secure communications room, or a Faraday cage for sensitive instrument calibration. It is also used around industrial RF sources such as induction heaters, plasma generators, and broadcast transmitters to protect nearby personnel and control systems. In research facilities it supports low-noise measurements for RFIC characterization, bio-electromagnetic studies, and sensitive receiver development where ambient noise would otherwise swamp the desired signal. Manufacturers use the room to validate that product emissions stay below regulatory limits before shipping units to certification laboratories.
Advantages
The welded design offers superior long-term attenuation because there are no gasketed panel joints that age, oxidize, or require re-torqueing. It provides high structural rigidity, excellent low-frequency magnetic attenuation, and resistance to physical tampering. Compared with modular clipped rooms, the welded room has a smaller leakage floor and is less sensitive to door cycling or building movement. KITOZER supports the enclosure with on-site weld quality inspection, shielding verification testing, and a 10-year structural warranty. The modular panel layout also allows future expansion by welding additional sections onto the existing shell. Because the shell is continuous, the room can be pressure-tested as a gas-tight volume where required for dust or cleanroom control.
Installation and Maintenance
Installation requires a flat, level concrete slab capable of supporting the steel shell weight, usually between 80 and 150 kg per square meter. Welding is performed by certified technicians and followed by a continuous weld penetration check and a spark test on all seams. After construction, a shielding effectiveness survey is conducted per IEEE 299, mapping leakage at every seam, door, filter, and waveguide. Routine maintenance is minimal: the shielded door gasket should be cleaned and inspected annually, power filters should be megger-tested every two years, and the grounding bond resistance should be recorded each quarter. No re-torqueing of panel fasteners is required because the shell is continuously welded. KITOZER also provides a trained service team for on-site leakage localization if future modifications ever compromise the shell.
Price
From $28,000 per room, depending on dimensions, attenuation grade, number of penetrations, and interior finish. Contact +86 13922289957 for a detailed quotation and site survey.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com