KITOZER
KITOZER

KITOZER Manual Shielded Door: 80dB Swing Type For Faraday Room

The KITOZER 80dB manual swing shielded door is the primary access component for welded and modular Faraday enclosures, EMC test chambers, and RF shielded rooms. When closed and latched, the door compresses a continuous beryllium copper fingerstock gasket around its entire perimeter, restoring the electrical continuity of the shielded shell and delivering at least 80 dB of attenuation from 14 kHz to 1 GHz. The manual operation keeps cost low and reliability high, because there is no motor, controller, or pneumatic system to maintain, making the door ideal for low-to-medium traffic shielded rooms where operators enter and exit a few times per day. KITOZER builds the door to match the attenuation of the room itself, so that the door does not become the weakest point in the enclosure.

Product Overview

The door leaf is a welded steel box section filled with structural stiffeners to prevent sagging over decades of use. The face is finished with powder coating or stainless steel laminate, and the perimeter is machined flat to within 0.5 mm so that it seats evenly against the gasket. A three-point or four-point cam-lock mechanism pulls the leaf uniformly against the gasket, ensuring that compression is consistent along all edges rather than only near the handle. KITOZER offers left-hand or right-hand hinges, single-leaf or double-leaf configurations, and optional vision windows, honeycomb vents, or pass-through hatches integrated into the leaf itself. The door frame is welded or bolted directly to the shielded room panels so that the gasket path is electrically continuous.

Technical Specifications

Standard leaf size is 1.0 m wide by 2.0 m high, with custom sizes up to 2.0 m by 2.5 m available. Shielding effectiveness is 80 dB minimum from 14 kHz to 1 GHz and 60 dB from 1 GHz to 18 GHz, verified per IEEE 299. Gasket is beryllium copper fingerstock with silver plating, rated for more than 100,000 cycles. Cam-lock is a three-point stainless steel mechanism with compression adjustable to 6 mm. Door leaf thickness is 100 mm, weight ranges from 120 kg to 250 kg depending on size. Hinges are heavy-duty stainless steel with grease fittings. Operating temperature is 0 C to 50 C. Optional door status contact sends a dry-contact signal to the room monitoring system when the door is open or closed.

Applications

The manual door is used on general-purpose EMC pre-compliance rooms, industrial RF shielded enclosures, secure equipment rooms, and research laboratories. It is the standard access solution for rooms that do not require high-frequency entry, such as storage areas for RF-sensitive instruments, calibration labs, and equipment staging rooms. Because there is no power requirement, the door also suits remote sites or temporary enclosures where electrical service to the door would be inconvenient. Double-leaf versions are used where forklifts or carts must enter the shielded room. The manual door is also popular in academic and training environments, where students learn Faraday cage construction and shielding fundamentals without the cost of powered hardware. Emergency response shelters and mobile test cabins rely on the same door because it operates without electricity during a grid outage.

Advantages

The manual door has the lowest acquisition cost and the lowest ongoing maintenance of any shielded door type. There are no electronic controls to fail, no compressed air to supply, and no safety light curtains to calibrate. The mechanical cam-lock provides positive feedback that the gasket is fully compressed, so operators can confirm shielding integrity before a test begins. KITOZER gaskets are field-replaceable without removing the door leaf, and the cam-lock mechanism can be re-tightened over time as the gasket compresses. The door is also tolerant of dirty or industrial environments where automated systems would be damaged by dust or moisture. KITOZER also supplies the door with a corrosion-resistant stainless steel option for coastal or washdown areas.

Installation and Maintenance

Installation requires the shielded room to be structurally complete and the floor level within 3 mm across the door opening. The frame is welded or bolted to the room panels, and the leaf is hung and adjusted so that the gap around the perimeter is uniform. Gasket compression is checked with a feeler gauge at four points along each edge, and the cam-lock is adjusted until compression reaches the factory specification. After installation, shielding effectiveness is measured at the door seam per IEEE 299. Maintenance consists of annual cleaning of the fingerstock gasket with contact cleaner, bi-annual lubrication of hinges and cam-lock, and replacement of the gasket every 5 to 10 years depending on traffic. KITOZER recommends keeping a spare gasket and handle set on site.

Price

From $4,200 per door, depending on size, attenuation grade, finish, and optional window or vent. Contact +86 13922289957 for manual shielded door quotation.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top