The KITOZER 100A single-phase power line EMI filter is the utility interface for a shielded room, Faraday enclosure, or EMC chamber, blocking conducted RF noise on the power feed while passing the mains current to equipment inside. Without this filter, the power cable acts as an antenna, coupling external interference into the room and coupling internal emissions out to the building mains. The filter uses a pi-network of X and Y capacitors with common-mode chokes, delivering more than 60 dB of attenuation across the 150 kHz to 30 MHz range and extending useful attenuation into the VHF band. KITOZER builds the filter into a steel chassis that mounts flush through the shielded wall, so that the filter body itself is bonded to the shielded shell and no unfiltered cable penetrates the room.
Table of Contents
ToggleProduct Overview
The filter is supplied as a wall-mount module with line and load-side terminal blocks, an integrated surge protection option, and a grounding terminal that bonds directly to the shielded room busbar. The enclosure is IP20 rated for dry indoor installation, and an IP54 option is available for industrial washdown environments. Inside, the common-mode choke is wound on a high-permeability core, and the X and Y capacitors are rated for mains voltage with safety certifications. KITOZER matches the filter to the room attenuation target, so that the combined leakage through the power entry stays below the specified shielding effectiveness. Optional status monitoring indicates over-temperature or over-current conditions.
Technical Specifications
Rated current is 100 A continuous at 40 C, single phase 230 V AC. Attenuation is 60 dB minimum common mode from 150 kHz to 30 MHz, and 40 dB differential mode. Leakage current is below 3.5 mA at 250 V 50 Hz. Operating frequency of the mains is 50 or 60 Hz. Insulation resistance is greater than 100 MW, dielectric test 2250 V AC between line and ground. Enclosure is 2 mm steel, powder coated, with flange mounting. Cable entries are knock-outs suitable for 35 mm to 50 mm glands. Operating temperature is -25 C to 55 C. The filter meets UL 1283, IEC 60939, and CE requirements.
Applications
This filter is installed on the power feed into EMC test chambers, MRI suites, TEMPEST rooms, RF shielded laboratories, and industrial Faraday enclosures. It is also used on the input to sensitive test instruments, medical equipment, and broadcast transmitters where conducted noise from the mains would otherwise disrupt measurements. KITOZER filters are commonly retrofitted to existing shielded rooms when leakage testing identifies the power entry as the weak point. The same module can be used on single-phase UPS feeds, lighting circuits, and HVAC controls entering the shielded space. Laboratory instrument racks also use the filter on their local branch circuit, because even a small leakage at the wall can swamp sensitive low-level measurements. The filter is equally suited to retrofitting older Faraday enclosures that were originally built without proper mains filtering.
Advantages
KITOZER power filters are factory-tested for attenuation per MIL-STD-220 or equivalent, and the test report is supplied with each unit. The steel enclosure bonds directly to the shielded wall, so the filter does not introduce a secondary leakage path through its own cable entries. The common-mode choke is sized for 100 percent overload for 60 seconds, protecting against inrush from UPS or motor loads. The filter is replaceable as a single module without rewiring the wall, and KITOZER offers a range of current ratings from 6 A to 600 A so that one product family covers every shielded room project. The filter also carries safety agency certifications that simplify building code acceptance, and the flange mounting pattern is standardized so that a KITOZER drop-in replacement fits most competitor cutouts.
Installation and Maintenance
Install the filter on the shielded wall, with the line side outside and the load side inside, and bond the enclosure to the room ground bar with a short, flat copper strap. Keep load-side wiring as short as possible and route it away from unfiltered cables. After installation, measure shielding effectiveness at the power entry per IEEE 299. Maintenance consists of annual inspection of terminal torque, megger testing of insulation resistance every two years, and visual check of the enclosure gasket. KITOZER recommends replacing the filter after 10 to 15 years of service, because capacitor dielectric ages even under normal load. A spare filter module on site also reduces downtime if a capacitor fails, because the unit can be swapped in under an hour without affecting the rest of the shielded room.
Price
From $680 per filter, depending on current rating, voltage, and certification. Contact +86 13922289957 for power line filter quotation and attenuation curve for your shielded room project today, and we will respond within one business day.