KITOZER
KITOZER

KITOZER PT1000 Temperature Sensor For HVAC And Cold Chain

The KITOZER PT1000 temperature sensor is a high-sensitivity platinum probe designed for HVAC, cold chain, and clean room applications where small resistance errors matter. With a nominal 1000 ohm at 0 degrees Celsius, the PT1000 element outputs ten times the resistance change of a PT100, which reduces the influence of long lead wires and allows 2-wire use in many installations. The compact ABS head suits wall-mount ducts, refrigerated display cases, and warehouse zones where a rugged stainless probe is unnecessary.

Product Overview

The KITOZER PT1000 line includes immersion probes, duct probes, surface mount probes, and room temperature transmitters. A 0 to 10V or 4 to 20mA transmitter option converts the element reading into a standard analog signal accepted by any building controller. All variants use a Class B thin-film element with optional Class A upgrade. The room version has a stylish ABS wall plate with a vented cover, suitable for offices, museums, and hospital wards.

The transmitter version uses a 16-bit ADC and linearizes the PT1000 curve onboard, so the BMS sees a linear signal without a lookup table. Power for the transmitter comes from the 24V BMS bus, and the loop draws under 5mA, allowing 20 transmitters on one 100mA supply. The room sensor housing is designed to blend into interior architecture: white ABS, low profile, and a removable vented cover that hides the sensing element behind a grille.

Technical Specifications

Sensor: PT1000 platinum, Class B per IEC 60751. Range: -50 to 200 degrees Celsius. Accuracy: plus or minus (0.3 + 0.005*t) degree. Output: raw PT1000, optional 4-20mA or 0-10V transmitter. Supply for transmitter: 12-36V DC. Probe: stainless sheath, 5 millimeter diameter, 100 millimeter standard length. Room version: ABS wall plate, vented. Protection: IP54 room version, IP65 duct version. Cable: 2 meter PVC. Certifications: CE, RoHS. Warranty: 2 years.

The 4-20mA version supports both 2-wire and 3-wire loop configuration, matching most BMS analog input cards. The 0-10V version suits VAV controllers that expect a voltage signal. Duct probes include a 200mm stainless steel stem and a flange plate that seals against the duct wall. Room sensors draw under 0.5mA, so they can share a thermostat bus with other room devices. All variants use the same PT1000 curve, which means a room sensor and a duct sensor from the same family read consistently when adjacent.

Application Scenarios

PT1000 sensors are common in VAV boxes, AHU supply and return air, refrigerated warehouse zones, walk-in cold rooms, wine cellars, pharmaceutical cold storage, and office room temperature loops. The 4-20mA variant connects directly to BMS analog inputs without additional converters. In food distribution, probes sit inside refrigerated trucks and containers to prove cold chain integrity. In laboratories, the room version supports controlled environment qualification testing.

In museums, room sensors protect paintings from temperature swings that accelerate varnish cracking. In clean rooms, multiple duct probes balance AHU output across zones. In hotel guest rooms, the PT1000 room sensor feeds the thermostat, replacing cheaper NTC sensors that drift over years. In breweries, immersion probes monitor fermenting tanks within plus or minus 0.5 degree. Each of these environments benefits from the low cost and broad availability of PT1000 spares.

Key Advantages

The 1000 ohm base resistance allows 2-wire connection on runs up to 100 meters without measurable error, which simplifies retrofit wiring. The optional transmitter eliminates analog scaling work in the BMS. Multiple form factors cover duct, immersion, surface, and room needs from one product family. Low cost per channel makes PT1000 the default choice when PT100 accuracy is not required. ABS room enclosures blend into office architecture instead of looking industrial.

Because PT1000 is supported by virtually every HVAC controller on the market, no special scaling table is required. The transmitter versions remove the need for analog input cards with built-in RTD support, which is a saving on legacy BMS. The vented room cover protects the element from touching but allows air circulation. Standard ABS dimensions match common thermostat back boxes, so retrofit installation does not require patching the wall. When selecting a PT1000 variant, choose the transmitter version if the BMS expects a 4-20mA or 0-10V signal, and choose the raw element version if the controller has a built-in RTD input card. Duct probes need a flange plate; immersion probes need a thermowell for pressurized pipes.

Installation and Maintenance

Mount duct probes through a gland in the side of the duct, with the tip pointing into the airflow and beyond the insulation layer. Surface probes use thermal compound and aluminum tape for good contact. Room sensors go on interior walls at 1.5 meter height, away from windows, radiators, and direct sunlight. Calibrate annually in an ice bath for the 0 degree check point, or against a reference chamber for full range. Inspect the vented cover on room sensors and clean dust every year.

Price

From $22 per room sensor, duct probe from $28, 4-20mA transmitter version from $45. Contact +86 13922289957 for project pricing.