KITOZER
KITOZER

KITOZER Electric Shielded Door: 100dB Motorized Swing Door

The KITOZER 100dB motorized shielded door combines high RF attenuation with powered operation for high-traffic shielded rooms where manual lifting of a heavy door would be impractical or fatiguing. An electric actuator swings the leaf open and closed, and a powered cam-lock system compresses the continuous beryllium copper gasket to a preset torque, removing operator judgment from the shielding integrity equation. The door is typically used on EMC test chambers, MRI suites, TEMPEST rooms, and production line shielded cells where staff pass through frequently and where consistent gasket compression is critical to repeatable test results. KITOZER designs the drive mechanism to fail safe, so that a power loss leaves the door either latched or safely operable manually.

Product Overview

The door leaf is a heavy welded steel box section, reinforced to resist deflection under the powered cam-lock load. A gear-motor actuator mounted in the frame swings the leaf through a 90 degree opening, and a secondary motor or pneumatic cylinder engages the three-point or four-point lock. Control is via push-button, key switch, RFID reader, or building automation signal. Safety devices include obstruction sensors, emergency stop buttons, and light curtains that prevent the leaf from closing on a person or cart. The control panel interlocks with the room test system, so that a test cannot start until the door is fully closed and the lock confirms gasket compression.

Technical Specifications

Standard leaf size is 1.2 m wide by 2.1 m high, with double-leaf options up to 2.4 m by 2.5 m. Shielding effectiveness is 100 dB minimum from 30 MHz to 1 GHz and 80 dB from 1 GHz to 18 GHz, measured per IEEE 299. Gasket is silver-plated beryllium copper fingerstock rated for 500,000 cycles. Motor is 24 V DC gear motor with clutch, lock force adjustable to 5 kN. Opening time is 8 to 12 seconds. Power requirement is 100 to 240 V AC, 500 W average. Control inputs include dry-contact start, door status, lock status, and emergency stop. Operating temperature is 5 C to 40 C. Optional pneumatic gasket actuation is available for MRI suites where electric motors near the scanner would be unacceptable.

Applications

The motorized door is specified for EMC test chambers where operators enter and exit dozens of times per day, for MRI suites where patients lie on carts that must be wheeled through, and for TEMPEST or secure rooms where controlled access is required. It is also used in shielded production cells for medical device or aerospace assembly, where material carts pass through on a fixed schedule. High-traffic contract test houses choose the motorized door because it reduces operator fatigue and eliminates variation in gasket compression between shifts. Biomedical imaging centers also specify electric doors for patient comfort, because staff can wheel a patient through without straining against a heavy leaf. The door is equally suited to shielded cleanrooms where hands-free operation reduces contamination risk.

Advantages

Powered operation removes human error from gasket compression, ensuring that every test begins with the same shielding condition. The lock status feedback closes the loop between door position and test software, preventing invalid data from a partially open door. KITOZER motors are sized for duty cycles up to 50 percent, and the gear train includes a manual override so that the door can be opened during a power outage. The safety system meets machine directive requirements, and the control panel is easily integrated with access control, CCTV, and building management platforms. Compared with a manual door, the motorized version pays back in reduced operator effort and fewer test re-runs. The controller also logs every open and close cycle, which KITOZER customers use for compliance records and for scheduling gasket replacement before cycle life is reached. A built-in self-test routine verifies that the lock force and safety sensors are within spec before each shift.

Installation and Maintenance

Installation requires power, control wiring, and a level floor. The frame is anchored to the shielded room, the leaf is hung, and the actuator and lock are adjusted so that gasket compression matches the factory spec. The safety light curtains and obstruction sensors are calibrated on site, and the control logic is verified with the room test system. Maintenance includes annual inspection of gaskets, semi-annual lubrication of hinges and gear train, and annual calibration of lock force. The motor brushes and clutch are inspected every two years. KITOZER recommends a preventive maintenance contract because the powered mechanism has more wearing parts than a manual door. A spare motor control board and a spare lock actuator are recommended on site for high-criticality rooms.

Price

From $12,500 per door, depending on size, attenuation, drive type, safety system, and integration scope. Contact +86 13922289957 for electric shielded door pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart