The KITOZER 250A three-phase power line filter is designed for the main power entry into large shielded rooms, EMC chambers, MRI suites, and industrial Faraday enclosures that draw substantial load across multiple phases. The filter suppresses both common-mode and differential-mode conducted noise on all three phases plus neutral, protecting equipment inside from the building mains and preventing internal noise from escaping to the utility grid. With 250 A continuous rating, it supports HVAC units, UPS systems, lighting distribution, and industrial machinery simultaneously through a single shielded penetration. The steel enclosure is flange-mounted through the shielded wall, and every internal component is rated for continuous industrial duty.
Table of Contents
ToggleProduct Overview
The three-phase filter uses a balanced pi-network across L1, L2, L3, and N, with common-mode chokes on each phase and a neutral. The enclosure is a heavy welded steel box with line and load-side terminal bars rated for 250 A, and a dedicated ground terminal bonded to the shielded room. KITOZER offers the filter as a wall-mount module or as part of a complete power entry cabinet with breakers, surge protection, and metering. The unit is designed for indoor installation in a dry environment, and the flange gasket ensures that the wall penetration itself is as attenuating as the rest of the shell.
Technical Specifications
Rated current is 250 A continuous at 40 C, three phase plus neutral 400 V AC. Attenuation is 70 dB common mode from 150 kHz to 30 MHz, 50 dB differential mode. Leakage current is below 5 mA. Insulation resistance exceeds 100 MW, dielectric test 2800 V AC. Terminal bars accept cables up to 240 mm square. Enclosure is 3 mm steel, flange mounted, weighing 45 kg. Operating temperature is -25 C to 55 C. The filter meets IEC 60939, UL 1283, and CE. Optional integrated surge protection is rated at 40 kA 8 by 20 microsecond impulse.
Applications
This filter is the standard main entry for 3 m and 10 m EMC chambers, MRI scanner suites that power gradient amplifiers and chillers, large TEMPEST rooms, and industrial shielded production cells. It is also used on the feed to shielded data center racks, broadcast transmitter halls, and plasma or induction heating enclosures. The 250 A rating comfortably supports a full chamber load including turntable, antenna mast, HVAC, and test instrumentation. KITOZER also supplies parallel filters for higher current rooms up to 630 A. Automotive end-of-line test cells and industrial drive enclosures use the three-phase filter to prevent conducted noise from variable frequency drives escaping to the grid. Broadcast transmitter studios also rely on the filter to keep studio power clean even when high-power transmitters share the same utility transformer. Shielded data center power distribution units also use the filter on each rack feed, so that server switching noise does not propagate back to the UPS. Medical device cleanrooms use it to prevent conducted noise from affecting sensitive patient monitoring equipment.
Advantages
The balanced three-phase design prevents noise from coupling between phases, which is a common failure mode in cheap filters that use single-phase chokes on three-phase lines. KITOZER units are tested with a full three-phase test setup, and the attenuation curve is supplied with the unit. The flange-mounted enclosure creates a 360-degree bond to the shielded wall, so the power entry does not become a slot antenna. The filter is serviceable from the load side without removing it from the wall, and replacement units are available from stock for fast turnaround. KITOZER also offers a version with built-in current monitoring, so that facility managers can track room load remotely. The balanced design also prevents triplen harmonic currents from circulating between phases, which reduces neutral heating in the shielded room distribution. KITOZER also supplies a matched power entry cabinet with breakers, surge protection, and the filter pre-assembled, which cuts wall wiring time for large rooms.
Installation and Maintenance
Install the filter with the line side outside the shielded wall and the load side inside, and bond the enclosure to the room ground bar with a braided strap under 300 mm long. Route load-side cables in shielded conduit or grounded cable tray, and keep them separated from signal cables. After installation, perform an IEEE 299 shielding test at the power entry. Maintenance includes annual torque check on terminal bars, insulation megger test every two years, and visual inspection of the flange gasket. KITOZER recommends a thermal imaging survey every three years to detect loose connections before they cause overheating. The filter ground bond should also be re-measured annually, because a loose bond can dramatically reduce high-frequency attenuation even when the low-frequency filtering appears normal.
Price
From $2,400 per filter, depending on current, voltage, and integrated options. Contact +86 13922289957 for three-phase filter pricing and a site power distribution review.