Table of Contents
ToggleProduct Overview
The KITOZER 13.56MHz Mifare IC card reader is a vandal-resistant outdoor reader designed to read Mifare Classic 1K, Mifare Ultralight, and CPU cards at a typical distance of 3 to 5 centimeters. Its sealed UV-stabilized polycarbonate housing withstands rain, sun, and temperature swings, making it suitable for building entrances, parking barriers, and gate posts. The reader outputs Wiegand 26 or Wiegand 34 data, configurable via the management software, and is compatible with every major access control panel on the market including KITOZER, HID, and generic Wiegand controllers. A bi-color LED and piezoelectric buzzer give clear feedback to users on accepted, denied, or tampered transactions. The slim profile fits narrow door frames and mullions where bulkier readers cannot be mounted.
How It Works
The reader antenna emits a 13.56MHz electromagnetic field. When a Mifare card enters the field, the card harvests energy from the reader and powers up its chip. The reader then performs an ISO14443A anti-collision sequence to read the card unique UID, optionally authenticates a sector key, and transmits the UID to the access controller over the Wiegand bus. The reader lights the green LED and beeps once on a valid card, and the red LED with a double beep on a denied or unenrolled card. The supervised data lines detect cut or shorted wires, and the reader sends a tamper signal to the panel if the housing is pried open.
Technical Specifications
Frequency 13.56MHz, ISO14443A protocol, card reading distance 3 to 5cm. Data output Wiegand 26 or Wiegand 34, selectable. Operating voltage 12V DC, current consumption 60mA typical, 100mA peak. Operating temperature -20C to 60C, humidity 10 percent to 90 percent. Front panel rating IP65. Dimensions 118mm by 48mm by 22mm, weight 90g. Cable length recommended up to 80 meters using 6-core shielded 22AWG wire. CE and FCC certified, five-year warranty.
Application Scenarios
This reader is installed at outdoor building entrances, parking barrier lanes, factory gates, dormitory doors, and warehouse exterior doors. It is also used as the exit reader in mantrap configurations, and as a secondary reader at elevator lobbies where floor access is card-controlled. Because it reads Mifare sector data, it is the preferred reader for cafeteria payment, library book checkout, and vending machine integration within a unified card system. The reader is also deployed at clubhouse gates, school side entrances, and hotel back doors where outdoor weather exposure is a concern.
Key Advantages
The IP65 sealed front means the reader survives direct hose-down and freezing rain, which is a common failure point for indoor readers installed outdoors. Mifare sector authentication prevents card cloning, a major security upgrade over simple EM-ID readers. Wiegand output compatibility removes vendor lock-in and lets integrators mix readers and controllers from different generations. The low 60mA current draw allows long cable runs without voltage drop. The compact slim profile fits on narrow door frames and mullions where larger readers cannot be mounted. The UV-stabilized cover resists yellowing after years of sun exposure.
Installation and Maintenance Recommendations
Mount the reader at a height of 1.4 meters on the door frame, at least 20 centimeters away from metal surfaces to avoid detuning the antenna. If the reader must be mounted directly on a metal plate, use the KITOZER anti-metal spacer. Run the 6-core shielded cable in a separate conduit from electric lock wires, and ground the shield at the controller end only. Set the Wiegand bit format to match the panel before enrolling cards. During commissioning, test at least 20 cards from different batches to confirm consistent read distance, and check that the buzzer and LED respond within 200ms. Clean the front panel with a soft cloth; avoid solvents that can cloud the UV-stabilized cover. Inspect cable connections annually for corrosion, especially in coastal installations. If read distance suddenly drops, check for metal objects newly installed near the antenna.
Troubleshooting FAQ
Q: The reader beeps red on every card. A: Verify the Wiegand bit format matches the panel, and confirm the card UID has been enrolled. If the format is correct but enrollment still fails, the card may be a different chip (EM instead of Mifare) and will not read on this reader. Q: Cards only read when held very close. A: A metal surface behind the reader detunes the antenna. Install the anti-metal spacer or move the reader away from the metal. Q: The buzzer is silent. A: Check the 12V supply at the reader terminals; if voltage is present but the buzzer is silent, the reader has suffered a surge and should be replaced. Q: The reader triggers false alarms at night. A: The data lines may be picking up interference from a nearby lighting circuit. Re-route the cable in separate conduit and ground the shield at the controller end.
Price
From $28/pc. Contact +86 13922289957 for volume reader pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com