The KITOZER NTC 10K temperature sensor is an economical thermistor probe used in HVAC controls, refrigeration, incubators, aquariums, and general equipment monitoring. With a 10 kiloohm nominal resistance at 25 degrees Celsius and a beta value of 3950, the sensor matches the most common NTC curve found on building controllers and thermostat boards. The small epoxy-bead tip responds quickly to air temperature changes, while the optional stainless immersion sleeve protects the bead in liquid or rough environments.
Table of Contents
ToggleProduct Overview
The KITOZER NTC family includes bead probes, stainless immersion probes, duct probes, and flange-mount boiler sensors. A 10K beta 3950 curve is standard, with 5K, 20K, and 100K options for legacy equipment. The epoxy bead version is waterproof after potting and costs very little, making it ideal for high-channel count projects. Stainless versions extend the range to 150 degrees and resist mechanical abuse.
Epoxy bead sensors are the cheapest temperature element available, which is why they dominate consumer appliances, automotive controls, and large HVAC projects where hundreds of points are needed. The bead itself is a tiny ceramic disc with printed silver electrodes, sealed in epoxy. KITOZER potted beads with a double seal, so they survive immersion in water up to 60 degrees. Stainless versions add a machined sleeve and spring-loaded tip for good thermal contact in pipes.
Technical Specifications
Sensor: NTC thermistor, 10 kiloohm at 25 degrees, beta 3950. Range: -40 to 125 degrees Celsius for epoxy bead, -40 to 150 for stainless. Accuracy: plus or minus 1 percent at 25 degrees, interchangeability 1 percent. Cable: 2 meter PVC, optional 5 or 10 meter. Response time: t90 under 10 seconds in air. Protection: epoxy bead IP67, stainless version IP68. Certifications: CE, RoHS. Warranty: 1 year.
The beta value describes the shape of the resistance curve between 25 and 85 degrees. A beta mismatch between sensor and controller causes a small but systematic error that grows at the edges of the range. KITOZER ships a one-page datasheet with the resistance table at every 10 degrees, so integrators can verify the curve against their controller. The stainless version uses a 6mm diameter 304 sheath, with a 1/8 inch NPT thread option for boiler and immersion wells.
Application Scenarios
NTC sensors are used in residential thermostats, mini-split AC units, refrigerator temperature alarms, aquarium heaters, reptile incubators, 3D printer hot ends, and electric vehicle battery packs. In commercial buildings, they feed VAV boxes and fan-coil units. In food service, they sit inside refrigerated display cases to trigger temperature alarms. The low price allows dense deployment across dozens of zones without blowing the project budget.
In indoor grow rooms, NTC probes monitor canopy temperature alongside humidity. In aquaponics, they track water temperature in fish tanks. In 3D printer farms, they watch hot-end and bed temperatures. In server room retrofit projects, NTC probes add cheap temperature points to existing racks before upgrading to a full Modbus sensor. The universal 10K beta 3950 curve means replacement parts are available from any HVAC supplier, not just KITOZER.
Key Advantages
The 10K beta 3950 curve is supported by virtually every HVAC controller on the market, so no special scaling table is required. Epoxy beads cost a fraction of a PT100, which matters when a project needs 500 sensors. Fast response suits control loops that react quickly to load changes. Wide cable length options reduce junction boxes on long runs. Stainless variants protect the bead without changing the electrical curve.
The main advantage is cost: at under $6 per probe, NTC is the only choice for projects where sensor budget dominates. Because the curve is industry-standard, local distributors stock compatible replacements, so a failed probe is swapped in minutes without waiting for a factory order. The epoxy bead survives accidental washing in kitchens and greenhouses. The stainless version handles boiler and solar thermal loops where the bead would melt. When specifying NTC, always confirm beta value and nominal resistance with the controller vendor; a 10K 3950 probe on a 10K 3435 input will read 2 to 3 degrees off across the range. For long cable runs beyond 10 meters, move to a 4-wire RTD instead of NTC, because lead resistance on a thermistor is harder to compensate. Keep a box of spare epoxy beads on site, since they cost less than a service call.
Installation and Maintenance
Confirm the controller expects beta 3950 before ordering; a mismatched curve causes several degrees of error. Mount the bead where it sees representative air, not near a heat source or cold draught. Seal cable entries in wet areas with heat-shrink tubing. Because NTC sensors drift slowly with age, schedule replacement every three to five years rather than recalibration. Keep spares on site since the cost of a truck call exceeds the sensor price.
Price
From $6 per epoxy bead probe, stainless immersion from $12. Contact +86 13922289957 for bulk and custom curves.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com