The KITOZER fire telephone system 10-line master station provides dedicated two-way voice communication between the fire control room and emergency telephone handsets located throughout a building. Unlike ordinary telephones, the fire telephone is continuously supervised and powered from the master station, so it remains operable during a fire when normal phone lines may be damaged. The 10-line capacity supports mid-size buildings, hotels, hospitals, and industrial facilities where firefighters need to communicate from remote points.
Table of Contents
ToggleProduct Overview
The master station is a rack- or wall-mounted unit with a handset, a numeric keypad, an LCD, and status LEDs for each line. It supervises up to 10 telephone handsets connected on a daisy-chained loop. When a handset is off-hook, the master station alarms and shows the point number. The master can also call any handset individually. Built-in power supply and battery backup ensure operation during mains failure.
Technical Specifications
Number of extensions is 10 expandable to 30. Line supervision is short and open circuit detection. Power input is 100 to 240 volts AC. Battery backup is 24 volts DC for 8 hours. Audio output is 1 watt. Enclosure is steel, rack or wall mount. Operating temperature is 0 to 40 degrees Celsius. Dimensions are approximately 482 by 266 by 90 millimeters for rack version.
Application Scenarios
Fire telephone systems are installed in high-rise buildings, hotels, hospitals, shopping malls, industrial plants, and underground parking. Handsets are located in stairwells, lobbies, electrical rooms, and at each floor landing. The system allows firefighters to report conditions, request resources, and coordinate with the control room without relying on mobile phones, which may fail in basements or during network overload.
Advantages
Supervised lines detect faults before an emergency. Dedicated hardware is not dependent on public telephone networks. The master station shows exactly which handset is calling. Battery backup ensures operation during power loss. Two-way communication supports coordinated firefighting. The system integrates with the fire alarm panel for automatic call routing.
Installation and Maintenance
Mount the master station in the fire control room. Run fire-rated cable to each handset in a supervised loop. After wiring, test each extension by off-hook and verifying the master station identifies the point. Test battery backup monthly. Inspect handsets annually for broken cords and dirty sockets. Replace batteries every 3 to 5 years. Keep the master station handset in its cradle when not in use.
Engineering Notes
Position handsets at exits, stairwells, and electrical rooms. Test off-hook signaling annually. Keep cords undamaged. Battery backup must be tested quarterly. Label each handset with its zone number. Train staff on handset use.
Code and Compliance
The fire telephone system must comply with local emergency telephone standards. Submit the extension layout for approval. Annual testing includes every handset. Keep a service log. Replace batteries every 3 to 5 years.
Warranty and Accessories
From $350 per 10-line master station. The station carries a two-year warranty. KITOZER supplies extension handsets, jacks, and expanders up to 30 lines. Spare batteries and handsets are available. Contact +86 13922289957 for extension handsets and larger systems.
Detailed Application Examples
A 10-line fire telephone master station serves a 10-story hotel, with handsets in each stairwell and lobby. Off-hook at any handset alarms the master and shows the point. Battery backup lasts 8 hours. Each handset is tested annually, and batteries are replaced every 4 years.
Long-term Operational Benefits
The fire telephone master station is a rugged, purpose-built system independent of the public telephone network, so it works when normal networks fail during an emergency. The handsets are simple mechanical units with no software. Battery backup ensures operation during power loss. Because it is supervised, faults are detected before they matter. A two-year warranty covers the master station.
System Integration
The fire telephone master station is a standalone supervised system independent of the public phone network. Each handset reports its identity to the master when off-hook, so the control room knows exactly where the call is coming from. The system also integrates with the fire alarm panel so that during an alarm, the master automatically connects the control room to the nearest handset. Battery backup ensures operation during power loss.
Price
From $350 per 10-line master station. Contact +86 13922289957 for extension handsets and larger systems.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com